3-9
Section 3 • Systems & Components Overview & Operation
255 Conquest
R
FRESHWATER VENT HOSE
FRESHWATER PUMP
VACU-FLUSH HEAD (OPTION)
CABIN SINK & FAUCET
Fresh Water System
Fig. 3.9.1
1
2
3
4
5
TRANSOM SHOWER
20 GAL. (76 L) WATER TANK
FRESHWATER FILL HOSE
6
4
5
6
7
7
Freshwater Pump
The fresh water pump
is located behind an
access hatch on the
aft wall of the cockpit.
To operate, depress
the “WATER” switch
located on the console
switch panel (See
fi gure 2.14.1). When
activated, the freshwater pump draws water from
the water tank and provides pressure to the transom
shower and cabin sink faucet.
Transom Shower
The transom shower head is located on the starboard
transom. The shower hose extends approximately 6’
(1.82M). The spray head is activated by depressing
the button on the back of the unit.
Maintenance
Very little maintenance is required for the freshwater
system, other than annual disinfecting and winterizing.
Periodically check the entire system to assure that the
hose connections, tube fi ttings, electrical connections
and mounting bolts are properly secured, and free
of chafi ng.
Transom Shower Unit
Fig. 3.9.2
1
2
PUSH BUTTON
6’ (1.82M) EXTENDABLE HOSE
1
2
1
2
Winterizing The System
If the water system will not be used for an extended
amount of time it is recommended that it be drained.
Draining the freshwater system will require you
to energize the freshwater pump switch on the
instrument panel, press the button on the freshwater
shower head and empty the freshwater tank. Next
disconnect the hoses to and from the water pump
to allow as much water as possible to drain out. De-
energize the fresh water pump switch. Some service
facilities may recommend filling the freshwater
system with a non-toxic, non-freezing solution. This
procedure should be completed by an authorized
service center.
Cabin Faucet
The faucet has a control knob on the right side of the
outlet which controls the fl ow of water.
Содержание 255 Conquest
Страница 2: ......
Страница 18: ...xviii 255 Conquest R THISPAGE INTENTIONALLY LEFT BLANK ...
Страница 90: ...4 6 255 Conquest Section 4 Electrical System R Switch Panel Diagram Fig 4 6 1 ...
Страница 91: ...4 7 Section 4 Electrical System 255 Conquest R DC Wiring Diagram Fig 4 7 1 ...
Страница 92: ...4 8 255 Conquest Section 4 Electrical System R Windlass Schematic Fig 4 8 1 Shore Power Schematic Fig 4 8 2 ...
Страница 94: ...4 10 255 Conquest Section 4 Electrical System R THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 106: ...5 12 Section 5 Care Maintenance R 255 Conquest THIS PAGE LEFT INTENTIONALLY BLANK ...