5-11
Battery Systems
Section 5
Bilge Pump System
Main 12 VDC power circuit 3 of 7
provides uninter-
ruptible power to the bilge pump switches located on
the helm station switch panel. The circuit is directly
connected to the
port
engine battery OFF-ON switch.
The connection is made on the
battery side
of the
battery OFF-ON switch and is always powered,
regardless of switch position.
The circuit is protected by one 20-amp, in-line blade
fuse located within seven inches of the port engine
battery OFF-ON switch.
This uninterruptible power circuit provides flexibility in
controlling your bilge pumps. With the port engine bat-
tery OFF-ON switch in the
OFF
position, you can still
operate your bilge pumps in the automatic or manual
mode.
See
Wire Color Chart
in this section for wire colors.