RULES FOR SAFE OPERATION

Be Educated:

All users must read and fully understand all information contained in this owner’s manual
before assembling, operating, or maintaining this air compressor. 

Avoid Moving Parts:

When the compressor is plugged into an electrical source and the pressure switch is in the
“ON” position, this compressor will cycle automatically.  
• Never touch any moving parts. 
• Keep all body parts, hair, clothing, and jewelry away from moving parts.  
• Never operate the air compressor without all guards and shrouds in place.
• Never stand on the compressor.

Attachments and Accessories:

For any attachment or accessory you will be using with this compressor, the maximum
allowable recommended pressure should be clearly marked on the product or should be
clearly noted within the operations manual. Exceeding the pressure rating of these
attachments (including, but not limited to:air tools, air operated accessories, spray guns, air
hose, air hose connections, tires and other inflatables) could cause them to fly apart or
explode and could result in serious injury.  
• Never exceed the maximum allowable pressure recommended by the manufacturer of any

attachment or accessory you use with this compressor.

Personal Protection:

The employer and/or user must ensure that proper eye protection is worn.  Eye protection
equipment must conform to the requirements of the American National Standards Institute
ANSI Z87.1-1989 and provide both frontal and side protection. 

NOTICE!:

Non-side shielded spectacles and face shields alone do not provide adequate

protection. Eye protection conforming to ANSI Z87.1-1989 will always be marked “Z87”.

CAUTION:

Additional Safety Protection will be required in some environments.  For

example, the working area may include exposure to noise level which can lead to hearing
damage.  The employer and user must ensure that any necessary hearing protection is
provided and used by the operator and others in the work area.  Some environments will
require the use of head protection equipment.  When required, the employer and user must
ensure that head protection conforming to ANSI Z89.1-1986.
•  Always wear eye protection.
• Wear proper hearing and head protection.
• Compressed air blast must never be aimed at anyone.  Compressed air can cause bodily

injury and can propel loose particles and small objects at high speed.

• Keep children away from area of operation.

Transporting:

Use the handle to move the compressor.  Do not drag or pull the compressor by the power
cord or air hose.  Always disconnect the air compressor before transporting.

3

Содержание CAP60PB-OF

Страница 1: ...ARNINGS AND INSTRUCTIONS KEEP THESE I N S T R U C T I O N S W I T HT H E T O O L F O RF U T U R E R E F E R E N C E I F Y O U H A V EANY QUESTIONS CONTACT YOUR BOSTITCH REPRESENTATIVE OR DISTRIBUTOR 174119REVB 11 07 OPERATION and MAINTENANCE MANUAL CAP60PB OF AIR COMPRESSOR Stanley Fastening Systems L P ...

Страница 2: ...nger indicates an imminently hazardous situation which if not avoided WILL result in death or serious injury Warnings indicate a potentially hazardous situation which if not avoided could result in death or serious bodily injury NOTICE Notice indicates important information that if not followed correctly could result in damage to equipment INDEX Safety Instructions 2 Rules for Safe Operation 3 4 E...

Страница 3: ...ou use with this compressor Personal Protection The employer and or user must ensure that proper eye protection is worn Eye protection equipment must conform to the requirements of the American National Standards Institute ANSI Z87 1 1989 and provide both frontal and side protection NOTICE Non side shielded spectacles and face shields alone do not provide adequate protection Eye protection conform...

Страница 4: ...OMPRESSOR WELDING ON THE AIR COMPRESSOR TANK CAN SEVERELY IMPAIR TANK STRENGTH AND CAUSE AN EXTREMELY HAZARDOUS CONDITION WELDING ON THE TANK IN ANY MANNER WILL VOID THE WARRANTY Ventilation WARNING RISK OF FIRE OR EXPLOSION DO NOT SPRAY FLAMMABLE LIQUID IN A CONFINED AREA SPRAY AREA MUST BE WELL VENTILATED DO NOT SMOKE WHILE SPRAYING AND DO NOT SPRAY WHERE SPARK OR FLAME IS PRESENT KEEP COMPRESSO...

Страница 5: ...t is not available The temporary adapter should be used only until a properly grounded outlet sketch A can be installed by a qualified electrician The green colored rigid ear lug or like extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box cover Whenever the adapter is used it must be held in place by a metal screw The motor of this compressor h...

Страница 6: ...oltage supplied to the compressor which could prevent the compressor from starting For optimum performance plug the compressor directly into an outlet and increase the length of airline as needed If an extension cord must be used use these guidelines Distance Needed Recommended Gauge Less than 25 ft 12 Gauge 25 50 ft 10 Gauge Greater than 50 ft Not Recommended 6 CAP60PB OF SPECIFICATIONS Motor 2HP...

Страница 7: ...o compress air B Tank Pressure Gauge The tank pressure gauge indicates the air pressure that is present in the tank in PSI lbs sq in C Regulated Pressure Gauge The regulated pressure gauge indicates the amount of pressure that is allowed into the discharge line E according to the setting of the regulator D Regulator Knob The regulator knob is used to adjust the air pressure that is available at th...

Страница 8: ...e air tool Shut Off Procedures 1 Push in the On Off switch to the Off position GENERAL MAINTENANCE Service and Maintenance Prior to performing service and maintenance to the compressor always disconnect all accessories and attachments from the unit and disconnect the compressor from the electrical source When replacing parts only use Genuine BOSTITCH replacement parts Notice This compressor is equ...

Страница 9: ...S ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IS LIMITED TO THE DURATION OF THIS WARRANTY BOSTITCH SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES This warranty is limited to sales in the United States and Canada Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so...

Страница 10: ...ther conditions Place compressor in warmer environment for at least 30 minutes typically temperatures below freezing then try restarting Air leaks at fittings Fittings loose Tighten fitting Check with soapy water DO NOT OVER TIGHTEN Air leak at pressure switch Clogged check valve Remove and clean check valve Unit will not build pressure Application requires excessive air demand Reduce demand on co...

Отзывы: