18
Plug the machine 15Amp input power lead into the
wall socket, ensuring that the power switch on
the machine is in the OFF position.
MACHINE SET UP STICK/MMA
6.Select Stick / MMA mode
3. Connect earth Clamp
to the terminal
2. Connect Electrode holder
to the terminal
Note: The below image shows setup for DCEP / Negative Polarity
(Most Common application)
1
2
Connect earth clamp firmly to work-piece
ensuring that the clamp makes good contact
with bare metal.
Take electrode holder and twist the handle to
open the lock. Insert bare metal rod end of
electrode and twist the handle to clamp
electrode.
3
4
Assemble Arc and Earth leads into the
welding terminals depending on requirements
of electrodes. Refer to your electrode packet
for polarity and current requirements.
• DCEP/ Negative Polarity (most common application)
- Earth clamp connector into the negative terminal.
- Electrode holder connector into the positive terminal.
•DCEN/Straight Polarity
- Earth clamp connector into the Positive terminal.
- Electrode holder connector into the Negative terminal.