BossPac WASP™ 

(Wireless Acceleration Sensor Puck) 

 

For use with the 

BossPac NEST™

 

 

 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

• Acceleration, Velocity, & Temperature

 

• CSA Class I Div 2*

 

• ATEX Zone 0 Pending 

 

 
 

 
 
 

 

Bay 8, 1450 - 28 Street NE,

 

Calgary, Alberta,

 

Canada

  

T2A 7W6 

Phone: +1 (403) 216-1226 Toll Free: +1 (866) 616-1226 Fax: +1 (403) 216-5557

 

www.bosspac.com

Содержание WASP

Страница 1: ... Puck For use with the BossPac NEST Acceleration Velocity Temperature CSA Class I Div 2 ATEX Zone 0 Pending Bay 8 1450 28 Street NE Calgary Alberta Canada T2A 7W6 Phone 1 403 216 1226 Toll Free 1 866 616 1226 Fax 1 403 216 5557 www bosspac com ...

Страница 2: ... WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS 1 DIVISION 2 WARNING EXPLOSION HAZARD DO NOT REPLACE OR REMOVE BATTERIES UNLESS AREA IS KNOWN TO BE NON HAZARDOUS WARNING STRONG MAGNET Strong magnetic field can cause personal injury or death to individuals with medical implants or other magnetic field sensitive medical conditions Keep tools and other metal obje...

Страница 3: ...o turn on and activate each sensor puck you must carefully attach the battery board to the sensor unit Plug the pins on the battery board into the corresponding connectors on the sensor puck See photo on the next page Once the pins make contact a LED on the underside of the battery module will flash to indicate power on During this time the WASP device performs a power on self test POST If all is ...

Страница 4: ...ow suggested measurement points for 3 types of machinery The WASPTM measures 3 axis by default Detailed recommendations for specific machine types are provided in ISO document 10816 The sensor pucks can be attached to the desired equipment by either magnet epoxy or stud mount When using the magnet mount place a small dollop of thermal paste on the center of the magnet prior to mounting The WASPTM ...

Страница 5: ...www bosspac com 5 ...

Страница 6: ... temperature to stabilize 3 Using a reference temperature source ie IR Temperature Gun1 record the temperature value at the valve cap at the mounting point of the WASP unit 4 At the NEST adjust the display temperature to match the value of the thermometer gun using the temperature calibration function See the section on temperature calibration in the Setting Temperature Warning Critical Error and ...

Страница 7: ...tside of the start up temperature window from 40 C to 100 C Ensure that the mounting point temperature is within the allowable temperature range and replace the battery as per the Battery Installation section of this manual If error persists the sensor may need to be replaced 4 Flashes Radio Failure Device could not initialize the radio Not user serviceably Replace sensor 5 Flashes Regulator Failu...

Страница 8: ...ust accept any interference including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique sub...