Parameters
Configuration
Select "configuration" and press "confirm" button, enter the parameters. FTC61
parameters, the user can up / down arrow key to page, select the parameter you want to
set, followed so as to achieve the best results.
Parameters Description
•
Speed
Stalls
:
Set the speed of the follower
o
Factory settings:
Third gear
o
Optional settings:
One file to six files
o
The higher the gear, the faster the speed. With a stepper motor, it is recommended
to select the second gear speed.
•
Sensitivity Level:
Set the sensitivity level of the follower reaction
o
Factor settings:
10
o
Optional settings:
1 - 30
o
The smaller
the value,
the lower the sensitivity
•
Follow the
Height
:
Set the following height
o
Factor settings:
1.0mm
o
Optional settings:
0.4 - 5.0mm
o
Process adjustment
•
Follow the Tolerance
:
The parameter is followed by the accuracy of the response
o
Factor settings:
50um
o
Optional settings:
0 - 500um
o
The larger the value, the more stable the results will follow, but poorer
repeatability; significantly cutting the zigzag sense.
It is recommended to set at/
between 50 to 150
.
•
Waiting for Height:
Set the cutting head to follow the completion of the docking height.
o
Factor settings:
20mm
o
Optional settings:
10-99mm
•
Perforation Method:
Set the punch mode
o
Factor settings:
Segmented perforation
o
Optional settings:
Segment perforation / progressive perforations
•
Perforation Height:
Set the hole height
o
Factor settings:
3.0mm
o
Optional settings:
1.0 - 5.0mm
FTC61 SERIES MANUAL
Document Number: 855-910
Revision: 001 Revision Date: 6/1/2019
BOSSLASER - PAGE 4 of 12