Wiring Port Diagram
•
-24V
:
24V DC input negative
•
PGND
:
DC power supply ground
•
+24V
:
24V DC input positive
•
CA
:
Calibration / Perforated multiplexed signal. Dry contact signal.
•
TR
:
Once connected, the FTC controls cutting head to set the following
position / began to
follow. Dry contact signal.
o
Connect: Start follow
o
Disconnect: Stop follow. Back to the waiting position.
•
0V
:
Input signals in public 0V
•
ZUP
:
On the move signals, follow the process
o
Signal connected system controlling the cutting head.
•
ZDN
:
To move the signal, follow the process
o
Signal connected system controlling the cutting head down.
•
0V
:
Input signals in public 0V
•
UL
:
Z-Axis maximum signal. Dry contact output signal.
o
Connect: Upper Limit
o
Disconnected: No Limit
•
LL
:
Z-Shaft lower signal. Cutting head dropped to the lowest level.
•
COM
:
Output signal of the common terminal. Voltage range: 0 ~ 36 V
•
K1
:
Anomaly alarm output signal. Notify CNC system downtime.
o
Connect: System failure
o
Break: Normal
•
K2
:
Follow the signal to / Calibration complete. Signal (Closed 1s)
o
Access: Reached the following location
o
Disconnect: No position is to follow
•
K3
:
Piercing signal. Dry contact output signal.
o
Access: Reached the hole position
o
Disconnect: "No" to the piercing location
•
SG
:
Shielded signal cable
•
PUL
(
+
):
Motor control pulse signal
•
PUL
(
-
):
Motor control pulse signal
•
DIR
(
+
):
Motor direction control signal
•
DIR
(
-
):
Motor direction control signal
•
Aviation plug
:
Capacitance signal.
•
GND
:
Computer communication serial port RS232
•
RX
:
Computer communication serial port RS232
•
TX
:
Computer communication serial port RS232
Port Definition
FTC61 SERIES MANUAL
Document Number: 855-910
Revision: 001
Revision Date: 6/1/2019
BOSSLASER - PAGE 2 of 12