Dosing
15
Setting the dosage in continuous operation
(Continuous mode)
•
Install device (see page 13)
•
Set the device to the default settings (see page 13)
•
Fill cartridge (see page 17)
•
Switch on the power switch (1)
•
Set operating mode to «Continuous»
•
Remove the valve gate (26)
•
Press and hold the foot switch (18)
•
Use the pressure regulator (2) to increase from 0
to the required quantity
•
For low-viscosity products, set the vacuum to prevent the product from escaping
from the cartridge when removing the valve gate (26) and mounting the dosing needle (27).
Allow 1 or 2 drops to flow out of the dosing needle.
Then use the vacuum regulator (3) to slowly adjust the vacuum.
Turn counterclockwise:
The back pressure increases.
Turn clockwise:
The back pressure decreases.
Depending on the viscosity and size of the cartridge, the vacuum will have to
be adjusted again
If the vacuum is set too high – when dosing with no piston – the medium can escape from the
cartridge into and damage the dosing unit.
Press the foot switch (18) repeatedly with the pressure regulator (2) to increase the dosing pressure gradu-
ally from 0 until the required quantity is reached.
If the required dosage is not reached, repeat the repeat the steps using larger or smaller dosing nozzles.
1.
Netzschalter On/Off
2.
Druckregler
3.
Vakuumregler
4.
LED
5.
Display
6.
Kartuschenanschluss
7.
Menutaste
8.
Entertaste
9.
Pfeiltaste auf
10.
Pfeiltaste ab
11.
Netzanschluss
12.
Schnittstelle ext. Steuerung
13.
Initiatoranschluss
14.
Druckluftanschluss
15.
Leistungsschild
Frontseite
1
3
5
4
7
9
2
6
8
10