Technical Data

 

Target Gas 

Range 

Low alarm 

High alarm 

Resolution 

          CH

4

 

0

100%LEL 

20%LEL 

50%LEL 

1%LEL 

H

2

0

100ppm 

10ppm 

35ppm 

1ppm 

CO 

0

1000ppm 

50ppm 

150ppm 

1ppm 

O

2

 

0

30%vol 

19.5%vol 

23.5%vol 

0.1%vol 

Other gases needed, please contact supplier 

 
Gas sampling method: Pump suction type, natural diffusion type 
Response time:              Pump suction type T90

30s, natural 

diffusion type T90

60s 

Detecting gas:                Support 1~4 kinds of gas detection 
Accuracy:                       

≤±5% F.S. 

Indication:                        2.0 inch color display, resolution 320*240 
Alarm methods:              Acousto-optic vibrating display quadruple 

alarm, TWA/STEL alarm 

Data communication:      Support USB to connect to the upper 

computer of the computer to view data 

System language:          Support Chinese and English switching; 

other languages can be customized 

Working environment:    Temperature -10

~50

humidity<95%RH (no condensation) 

Power Source:                DC3.7V (Lithium battery capacity 

2500mAh) 

Charging way:                Type-C charging interface, 5V/1A standard 

charger 

Standby time:               

8h 

Charging time:                <5h 
Gas Sensor Life:            2 years 
Protection Grade:          IP65   
Weight:                            372.5g(include pump) 
Dimensions:                    Pump suction type 160*69*75mm; natural 

diffusion type 150*69*55mm 

Содержание BH-4M

Страница 1: ...BH 4M Portable Multi gas Detector User Manual Bosean Electronic Technology Co Ltd ISO9001 2015...

Страница 2: ...sites For the requirements of high reliability of the equipment the shell is made of high precision engineering plastics and non slip rubber with high strength and good hand feeling It can be widely...

Страница 3: ...ons to meet users different product applications 2 2 Functions Sound light vibration and display four alarm modes It supports switching between real time gas concentration data display and real time c...

Страница 4: ...gas detection Accuracy 5 F S Indication 2 0 inch color display resolution 320 240 Alarm methods Acousto optic vibrating display quadruple alarm TWA STEL alarm Data communication Support USB to connect...

Страница 5: ...ture It is mainly composed of shell circuit board battery display screen sensor charger and other components 4 2 Sensor working principle Electrochemical and catalytic combustion 5 Function and operat...

Страница 6: ...l etc heat When the preheating is completed enter the main detection interface of the detector Figure 2 Figure 1 Figure 2 5 2 Turn off In the main menu interface of the detector press and hold the mid...

Страница 7: ...icon is green when the gas concentration detection is in the low or high alarm state after pressing Mute the icon turns red d Battery level indicator The battery level is divided into six bars When t...

Страница 8: ...he alarm lights on both sides of the screen flash synchronously and the vibrator vibrates If the screen is in the off state the screen lights up at the same time When the detector detects that the gas...

Страница 9: ...tion is turned on if a new alarm state occurs the buzzer will resume ringing When the gas concentration detected by the detector returns to the lower limit alarm value the gas concentration value colo...

Страница 10: ...ace you can view the real time detection curve of a certain gas channel within 10s Click the left or right button to switch the channel display and click the middle button to return to the main interf...

Страница 11: ...ce or status bar The start operation of the setting object The finish operation of the setting object Down shift function UP shift function Right shift function Perform calibration settings Occurs whe...

Страница 12: ...o each channel Calibration Perform calibration operations such as calibration and zero adjustment on the relevant channel gas System setting Set time language backlight air pump and other system param...

Страница 13: ...igure 12 The left side of the figure shows the gas options and the right side shows the alarm settings Follow the instructions in the navigation bar to set the operation There will be a corresponding...

Страница 14: ...n period of time After the value is stable click the middle button to confirm and save There will be a corresponding prompt on the screen when the save succeeds or fails Figure 17 Zero drift After the...

Страница 15: ...language setting pump setting Figure 19 Time setting Follow the navigation bar prompts to set the system time Figure 19 Backlight setting Set the brightness of the instrument s backlight there are th...

Страница 16: ...o low Please charge or the detector cannot be turned on normally due to undervoltage please charge in time when the detector is off connect the charger plug to the charging jack of the detector and th...

Страница 17: ...the test site so as to avoid unplugging and plugging the charger Sparks cause fire or explosion 7 Possible fault and corresponding solution Possible fault Possible reason Corresponding solution The d...

Страница 18: ...se calibrate or replace the gas sensor Minus gas level displayed Gas sensor drift Calibrate zero point Sensor fault indication Sensor fault Please contact the manufacturer or dealer to replace the gas...

Страница 19: ...and hard objects otherwise it may cause scratches or damage to the instrument surface f In order to ensure the detection accuracy of the instrument the instrument should be calibrated regularly and th...

Страница 20: ...ean com Tel 86 371 86533226 Email sales bosean com 19 Henan Bosean Electronic Technology Co Ltd No 228 West 4th Ring National High Tech zone Zhengzhou China Tel 86 371 86533226 Fax 86 371 86533226 E m...

Отзывы: