![Bose Panaray 502A Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/bose/panaray-502a/panaray-502a_service-manual_2792471055.webp)
55
Troubleshooting Tips (continued)
With a nominal AC power input voltage (100, 115, or 230, depending on the country), the AC
voltages at the transformer secondary between P3-1 and P3-3 should be 41.3 Vrms.
With a cold (i.e.-room temperature) power transformer, you should expect primary and second-
ary resistances of:
For the 100 VAC version:
between P2-1 and P2-2: 41.8 Ohms
between P3-1 and P3-3: 6.9 Ohms
For the 115 VAC version:
between P2-1 and P2-2: 45.4 Ohms
between P3-1 and P3-3: 6.3 Ohms
For the 230/240 VAC version:
between P2-1 and P2-2: 195 Ohms
between P3-1 and P3-3: 7.1 Ohms
Other DC voltages that are of use in troubleshooting:
Turn On/Off Muting Circuit
Typical DC voltages after 2 seconds wake up
U15-1
Section not used
U15-2
+13.5
U15-3
-15.0
U15-4
+.15
U15-5
+3.2
U15-6
Section not used
U15-7
Section not used
U15-8
+7.5
U15-9
+13.5
U15-10
+7.5
U15-11
+9.7
U15-12
-15.0
U15-13
+13.5
U15-14
-13.9
Q1-collector
-14.7
Power Supply
U13-1
+26.0
U14-2
-26.0
THEORY OF OPERATION
Содержание Panaray 502A
Страница 16: ...16 Figure 5 502B Bass Box Exploded View...
Страница 19: ...19 Figure 7 502C Controller Exploded View removable front panel version...
Страница 33: ...33 Figure 10 502A Array Wiring Diagram SPEAKON XLR BARRIER...
Страница 37: ...37 Figure 11 502B Bass Module Exploded View...
Страница 39: ...39 Figure 13 502B Bass Module Wiring Diagrams SPEAKON WIRE DIAGRAM...
Страница 52: ...52 Figure 25 CVT 5 Schematic...