Boschetti Industrie Meccaniche srl
18
IT
Ver. 01/2018
Burner’s injector
Burners injectors replacement
This operation must be carried out only by a qualified staff. You have to follows these directions:
- remove the cover for gas valve and unscrew the related fixing screws;
- dismount the burners protection mask;
- loosen in sequence: the thermocouple, the valve-pilot's gas tube and the valve-burner's gas tube;
- Unscrew the fixing screws and remove the support box with burners and pilot;
- remove the locknuts;
- dissamble with a suitable key the injectors of the burners and replace them with the right ones fixing the connections;
- set all the parts by following the opposite procedure.
- set the pressure to the injectors according to technical data scheme at page 4. (see paragraph at pag. 10 “Control
pressure outlet gas (Injectors pressure)”).
Picture 14
Burners injectors replacement
Locknut
Burner’s injector
Locknut
Two burners
Valve-burner's
gas tube