4.0

Programming

Program the address DIP switches as described for the control panel you are using.

Note:

When installing the ZX835 with a D7212B1, D8112, or D9112B1; place switch number “0” in the ON position.

Recommended point type programming:

D8112 = 7571
D9112B1/D7212B1 = Point type 2, point response 2, no ring until restored.
D9412/D9112 = Point type 2, point response E, no ring until restored.

5.0

Wiring

Apply power after all connections have been inspected.  Do not coil excess wiring inside.  Plug the wire entrance hole
with the foam plug provided after all wiring connections have been made.

6.0

LED Operation

The detector uses a tri-color LED to indicate the various alarm and supervision trouble conditions that may exist

If the detector experiences a Microwave or PIR self-test failure, it is in need of replacement.

During walk testing, the LED will light for the first technology (microwave or PIR) and then light red to indicate a detector alarm. The LED
will not indicate activation of the second technology by lighting its color.

7.0

Feature Selection

LED On/Off Pins

:  The ON position allows operation of the tri-color LED.

If the tri-color LED indication is not desired after setup and walk tests are
completed, place the plug in the OFF position. The OFF position does not
prevent the tri-color LED from indicating a supervision trouble condition.

PIR Sensitivity Selection Pins

:  The PIR response sensitivity may be selected

by placing the plug across the pins marked (STD) for Standard or (INT) for
Intermediate mode.

-

Standard Sensitivity:  The recommended setting for maximum false alarm immunity.  Tolerates environmental
extremes on this setting.

-

Intermediate Sensitivity:  The recommended setting for 

non-pet

 applications where an intruder is expected to cover

only a small portion of the protected area. Tolerates normal environments on this setting. This setting will improve
your intruder catch performance.   (Recommended for higher mounting heights).

8.0

Setup and Walk Tests

Select the vertical starting angle from the chart. To adjust the vertical starting angle for the desired mounting height and range, loosen the
vertical adjust screw and slide the board up, to point the angle down. Note the settings on the vertical adjust scale.

CAUTION

LED

CAUSE

Steady red

Unit alarm

Steady yellow

Microwave activation (walk test)

Steady green

PIR activation (walk test)

Flashing red

Warm-up period after power-up

Flashing red (4-pulse sequence)

Microwave or PIR failure; replace unit

Содержание ZX835

Страница 1: ...from outside traffic roads alleys Remember Microwave energy will pass through glass and most common non metallic construction walls Avoid installations where rotating machines e g ceiling fans are normally in operation within the coverage pattern Point the unit away from glass exposed to the outdoors and objects that may change temperature rapidly Remember The PIR detector will react to objects ra...

Страница 2: ...operation of the tri color LED If the tri color LED indication is not desired after setup and walk tests are completed place the plug in the OFF position The OFF position does not prevent the tri color LED from indicating a supervision trouble condition PIR Sensitivity Selection Pins The PIR response sensitivity may be selected by placing the plug across the pins marked STD for Standard or INT for...

Страница 3: ...he board up will angle the pattern downward Tighten the screw snug when positioning is completed Note The pattern may be moved 10 horizontally by moving the lens window left right 8 2 Establishing Microwave Coverage Note It is important to wait one minute after removing replacing the cover so the microwave portion of the detector can settle and to wait at least 10 seconds between the following wal...

Страница 4: ...n lens is not recommended for installations containing pets or small animals The Look Down finger is shown in black below 12 0 Special Instructions for Installations Containing Pets The ZX835 will provide reasonable protection from nuisance alarms caused by the following sources A dog up to 100 pounds 45 kg Up to 10 cats Two 60 pound 27 kg dogs Random flying birds Multiple small rodents such as ra...

Отзывы: