Repairs
2013-10-23 / DIS 113_58300000133444_ara_en_l
Repair Instructions Laundry Repair Instruction;T22
Page 22 of 35
6.2
Installing conversion kit 743988
See video in the Quick Finder.
Prerequisite:
•
Heat pump and bearing shield have been cleaned.
•
Condensation tank with connection hose has been removed.
•
Double fluff filter 650474 has been installed.
6.2.1
Preparing conversion kit
► Transfer microswitch and plunger from the old carrier.
6.2.2
Installing conversion kit
1. Remove holder (Optional)
2. Install condensation pump and condensation sensor.
3. Install condensation tank housing.
4. Connect hose between condensation tank housing and condensation pump.
5. Insert double fluff filter.
Result:
Conversion kit has been installed.