6 720 606 599

Do not enlarge the orifice.

Do not use any wire or sharp object to clean orifices. Natural
gas  orifices  are  large  enough  that  you  can  usually  clean
them by blowing through them. To access the pilot orifice,
remove 2 screws holding pilot assembly in place. Then loosen
compression fittings to expose pilot orifice.

Heat Exchanger

 should be visually examined once a year

or  more  often  in  dusty  areas.  If  fins  at  top  show  dust  or
debris accumulation, remove and clean with brush and soapy
water.

Fig. 12 - Characteristic Pilot Flame

To clean the pilot burner and/or the pilot orifice: 

Turn off

the gas to the unit. Set the On/Off switch to Off (position

). Remove the cover of the heater. To do so, pull off the

temperature adjustment knob and unscrew and remove the
plastic collar. Pull main cover out toward you and lift up and
out. The pilot orifice should be cleaned or replaced.

Main  Burner  Flames:

  The  main  burner  flames  should  be

blue, with a more intense blue cone in the center core. Yellow
flames  could  be  a  sign  of  plugged  or  dirty  burners,  or  a
blockage on the heat exchangers fins. If some burners have
yellow flames while others have good flames, it is likely that
dust, lint or spider webs have partially clogged the burner
venturis. To clean the burners, contact a gas service person.

Mineral  Scale  Build-up:

  In  hard  water  areas  the  Bosch,

when operated at lower temperature settings, tend not to
accumulate mineral buildup. If however, the heater is used
at the higher temperature settings and the water has a high
mineral content, periodic descaling may be necessary. The
heating coil should be removed and flushed with a descaling
solution. Signs of scaling are rising outlet temperature and
knocking noises when water is flowing.

Flue gas safety device:

The flue gas safety device must not under any circumstances
be  switched  off,  simulated  or  replaced  by  any  other
component.

Operation and safety precautions

The flue gas safety device checks the effectiveness of flue
gas extraction by the flue. If it is inadequate, the appliance
switches off automatically so that the combustion fumes do
not escape into the room in which the appliance has been
installed. The flue gas safety device resets after a cooling-
down period.
If the appliance shuts down while in operation, ventilate the
room. Wait about 10 minutes then restart the appliance. If
the problem recurs, call an engineer. The user must never
make any modifications to the appliance.

Removal of the Heat Exchanger
1

.  Shut  off  the  gas  and  water  cold

supply lines to the heater and remove
the  front  cover.

2

. Remove the drain screw from the

bottom  of  the  water  regulator  and
open the hot water tap to allow the
unit  to  drain.

3

. Remove cover and unscrew metal

retaining  bar  at  the  top  front  of  the
heat  exchanger

4

.  Undo  water  connection  nuts  at

heat  exchanger  from  both  sides

5

Tilt the heating body to the front

at  the  top  and  lift  away  from  the
heater.

Estimated service time is 10 minutes to re & re, plus cleaning time

MAINTENANCE AND SERVICE

Approximately once a year, the Bosch should be checked,
cleaned and serviced as necessary. To remove the front cover,
first remove the incandescent particle tray, then pull off the
temperature adjustment knob and unscrew and remove the
plastic collar. Pull main cover out toward you and lift up and
out.  THE  FOLLOWING  OPERATIONS  SHOULD  BE
PERFORMED BY A QUALIFIED SERVICE PERSON:

Vent System:

 Should be checked annually. Clean and repair

as needed. See Preventative Maintenance Page 11.

Water  Valve

:  The  water  valve  on  this  heater  should  be

serviced  periodically.  The  frequency  will  depend  on  the
mineral  content  of  the  water  and  conditions  of  use  or
whenever signs of corrosion appear at the gas and water
valve joint. Check that the water inlet filter (#36 on Figure
18, page 20) is clean. Diaphragm should be replaced every
7-8 yrs. in residential applications and 3-5 yrs for commercial
applications. In acid water areas the venturi should also be
replaced at the same time (#30 on Figure 17, page 21).

Pilot Flame:

 The pilot flame should burn with a clean, sharp,

blue flame and should resemble the diagram in Fig. 12. If
the flame is soft and yellow the pilot screen may be dirty or
the pilot burner orifice may need to be cleaned or replaced.
The  pilot  flame  should  be  approximately  2  inches  long,
extending past the flame sensor. If the flame is too small, it
will  not  reach  the  flame  sensor  and  the  burners  will  not
come on.

3mm

Correct  gap  between
pilot  burner  tip  and
electrode  tip

Sparking plug
electrode

Flame  sensor

Sparking
plug
electrode

Pilot cap orifice

Pilot tube

Содержание WR430-7K

Страница 1: ...ontact your salesman or installer NOTICE TO INSTALLER Please leave this manual with the owner or affix adjacent to appliance Instantaneous gas water heater WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damge personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any o...

Страница 2: ...the same time a microswitch is activated which sends a spark to the pilot The flame sensor confirms that the pilot has been lighted and allows burners to ignite The pilot goes out The power exhaust system runs as long as the burners are on The heat exchanger coils absorb the heat generated by the burners and transfer heat to the water When the hot water faucet is shut off the gas valve automatical...

Страница 3: ...ings and are valid only in Canada In the U S the National Fuel Gas Code ANSI Z223 1 1988 recommends for high altitude installations above 2 000 feet that the input rate be reduced 4 for each 1 000 feet above sea level See page 15 EXTERIOR TERMINATION Model Type of Gas Altitude Input Size mm Qt natural gas 130 000 Btu hr 38 kW 1 20 diam 18 propane LP 125 000 Btu hr 36 6 kW 0 79 diam 18 natural gas ...

Страница 4: ...an cause dust build up in the finned heat exchanger and result in damage to heater and be a hazard to health The BOSCH instantaneous gas water heater is designed to operate on natural or propane gas however make sure that gas on which heater is to operate is the same as specified on the heater s model rating plate In addition to these instructions the water heater shall be installed in accordance ...

Страница 5: ...line and other flammable vapors and liquids 2 Do not obstruct the flow of combustion and ventilation air to the appliance CLEARANCE The WR430 7K is design certified for installation on a combustible wall and for installation in an alcove or closet with minimum clearances to combustible construction of 0 mm from back 102 mm 4 inches from sides 305 mm 12 inches from top and bottom and 102 mm 4 inche...

Страница 6: ...odified in any way when installing the Power Vent System All systems must be installed as per Bosch Installation Guide Installation other than instructed in this manual CAUTION Bosch Power Vent System must be installed by a qualified agency in accordance with these instructions If improperly installed a hazardous condition such as an explosion or Carbon Monoxide poisoning could result Bosch will n...

Страница 7: ...ust be installed for internal wall applications All runs through unheated space or exposed to outside temperatures must be insulated to prevent condensation All portions of the vent system under positive pressure during operation on the outlet side of the WR430 7K shall be sealed with high temperature silicone and high temperature aluminum duct tape and installed so as to prevent leakage of flue o...

Страница 8: ... buildings and that proper clearances are maintained See Fig 2 a The vent terminal of this Power Vent System shall not be less than 7 feet 213cm above grade when located in areas accessible to public walkways b A vent terminal shall terminate at least 3 feet 91cm above and a minimum of 10 feet 305cm horizontally from any mechanical air inlet c The vent terminal shall not be within 6 feet 183cm rad...

Страница 9: ... each joint Please note that wherever possible use continual lengths of pipe to reduce the number of joints 5 Seal all positive vent pipe and elbow joints between Bosch unit and vent terminal with high temperature silicone and or hi temperature aluminum tape following manufacturer s instructions i e always push silicone ahead of nozzle ELECTRICAL WIRING 1 The electrical contact ratings are as foll...

Страница 10: ...osch cover and towards draft hood If the vent is drawing properly the smoke or match flame will be drawn over the top edge of the Bosch cover and into the draft hood or opening see drawing below Checking The Draft NOTE If smoke is not drawn in then the combustion products are escaping from the relief opening into the room Under these conditions the equipment shall not be operated until proper adju...

Страница 11: ...emove all foreign material from vent system before operation 3 Spill Switch Verify proper spill switch operation by observing Operation Sequence and by temporarily blocking termination outlet 4 Check Draft Check for flue gas spillage following steps in the Operation And Checking Draft on page 9 5 Vent Termination Inspect to ensure installation and clearances have not been altered or obstructed and...

Страница 12: ...aters are provided with two S bend water connectors adaptors that must be connected to inlet and outlet connections on water valve assembly see Figure 4 below Figure 4 The purpose of the S bend water connectors adaptors is to provide threaded water connections that meet standards used in North America ANSI Standard Taper Pipe Thread 1 2 NPT The cold water supply should be connected to S bend attac...

Страница 13: ... outside vent valves are protected against blockage These are part of the gas supply system not the water heater Vent blockage may occur during ice storms Figure 7 Gas Burner test point D for measuring burner manifold pressure at full flow and input Standard Altitude 4 58 W C Nat Gas 9 11 W C Propane High Altitude 3 73 W C Nat Gas 7 27 W C Propane GAS CONNECTIONS Before connecting the gas supply t...

Страница 14: ...ance with the instructions on the Lighting and Operating Plate on the water heater For your convenience the instructions are repeated here LIGHTING AND OPERATING INSTRUCTIONS 1 STOP Read the safety information above on this lable 2 The gas valve must be shut off by putting the ON OFF switch to position Wait five 5 minutes to clear out any gas If you smell gas STOP Follow B in the safety informatio...

Страница 15: ...ft above sea level the manifold pressure should be reset at installation to the value shown on the rating plate or Table 1 below for standard altitude Increases temperature and decreases flow Temperature Adjustment Knob Decreases temperature and increases flow REGULATOR SUPPLY TEST PRESSURE TAP T ADJUSTABLE PRESSURE REGULATOR Figure 11 Principles of Operation With the water flow selector turned to...

Страница 16: ...safety device resets after a cooling down period If the appliance shuts down while in operation ventilate the room Wait about 10 minutes then restart the appliance If the problem recurs call an engineer The user must never make any modifications to the appliance Removal of the Heat Exchanger 1 Shut off the gas and water cold supply lines to the heater and remove the front cover 2 Remove the drain ...

Страница 17: ...e at faucet is below minimum flow needed to activate heater When temperature adjustment knob is turned all the way clockwise the Bosch WR430 7K requires 1 2 gallon per minute flow to activate the heater As a reference this is a flow which would fill a quart jar in 30 seconds If the temperature adjustment knob is turned fully counterclockwise a flow rate of 1 1 gallons minute is required to activat...

Страница 18: ...k that venturi is free of dirt particles Water valve and component parts must be totally free of dirt In hard water areas mineral deposits can eventually 3 5 years in hard water areas corrode the water valve parts to a point where they will need replacing Any sign of moisture at the top of the water valve is a sign that the water valve needs to be serviced immediately 9 Loose connection at the ECO...

Страница 19: ...r inlet pressure 60 psi max for best results or due to acid water erosion of venturi Check venturi Part 39 Fig 19 page 20 3 Btu input is too low due to insufficient gas pressure It is extremely important for a tankless instantaneous water heater to have the right size gas line to obtain the correct gas pressure See specifications on page 15 table 1 Unlike storage tank water heaters the burners of ...

Страница 20: ...s pressure test nipple 4 Main gas burner 5 Pilot gas tubing 6 Gas valve 7 Electronic control box 5 11 1 4 9 10 12 2 6 8 7 13 3 See fig 7 page 13 See table 1 on page 15 8 Power cord 9 on off switch 10 Temperature adjustment selector 11 Microswitch 12 Gas inlet gas pressure test nipple 13 Exhaust Fan ...

Страница 21: ...21 6 720 606 599 ...

Страница 22: ... pipe 8 700 707 349 14 Washer 8 700 103 173 15 Gasvalve 8 707 021 069 NG 15 Gasvalve 8 707 021 068 LPG 16 Diaphragm switch 8 708 504 021 NG 16 Diaphragm switch 8 708 504 049 LPG 17 Pilot valve 8 708 501 249 18 Servovalve 8 708 501 250 19 Cold water pipe 8 700 705 627 20 Centrifugal blower 8 707 204 023 21 Cable 8 704 401 168 22 Hot water pipe 8 700 715 080 23 Temperature limit 8 707 206 040 24 Wat...

Страница 23: ...23 6 720 606 599 Fig 17 INTERIOR COMPONENTS DIAGRAM AND PARTS LIST ...

Страница 24: ......

Страница 25: ...eau instantané à gaz AVERTISSEMENT Silesinstructionsdecemanuel ne sont pas scrupuleusement observées il pourra exister un risque d incendie ou d explosion susceptible de provoquer des dommages matériels et ou des blessures graves ou mortelles Ne pas remiser ou utiliser de l essence ou un autre produit inflammable liquide ou gazeux au voisinage de cet appareil ou de tout autre appareil ménager QUE ...

Страница 26: ...ultanément la manœuvre d un micro contacteur provoque la génération d étincelles pour l allumage de la flamme de veille Un détecteur de flamme détermine que la flamme de veille est allumée et permet ensuite l allumage du brûleur Ensuite la flamme de veille s éteint Le ventilateur d extraction fonctionne aussi longtemps que le brûleur est allumé Le serpentin de l échangeur de chaleur absorbe la cha...

Страница 27: ...on canadienne du gaz elles ne sont valides qu au Canada Aux É U la norme ANSI Z223 1 1988 National Fuel Gas Code recommande une réduction des valeurs de débit thermique de 4 pour chaque palier de 1000 pieds au delà de 2000 pieds au dessus du niveau de la mer Voir page 15 BOUCHE DE DÉCHARGE À L EXTÉRIEUR AVEC CLAPET Modèle Type of Gaz Altitude Débit thermique Dia mm Qt 130 000 Btu hr 38 kW 1 20 18 ...

Страница 28: ...ne quantité de poussière supérieure à la normale ceci pourrait provoquer une accumulation de poussière sur l échangeur de chaleur qui pourrait endommager l appareil et susciter des risques pour la santé Le chauffe eau instantané BOSCH est conçu pour être alimenté au gaz naturel ou au propane cependant on doit vérifier que le type de gaz disponible est celui qui est spécifié sur la plaque signaléti...

Страница 29: ...tes sont respectées pour les dégagements de séparation entre le chauffe eau et les matériaux combustibles 0 mm à l arrière 102 mm 4 po sur les côtés 305 mm 12 po au sommet et au dessous et 102 mm 4 po à l avant On doit également établir un espace libre d au moins 305 mm 12 po pour les interventions d entretien ou changement de pièces La valeur du dégagement de séparation à respecter autour du cond...

Страница 30: ...llé conformément aux instructions du guide d installation Bosch Installation réalisée non conformément aux instructions de ce manuel MISE EN GARDE Le circuit de décharge Bosch avec ventilateur d extraction doit être installé par une personne qualifiée en conformité avec les présentes instructions Toute installation incorrecte peut susciter l établissement d une situation dangereuse comme risque d ...

Страница 31: ...le doit être installée Une section de conduit traversant un espace non chauffé ou exposé à la température extérieure doit être isolée pour la prévention de la condensation Toute section du circuit de décharge exposée à une pression positive durant le fonctionnement du chauffe eau du côté décharge du chauffe eau WR430 7K devra être scellée avec un matériau de silicones résistant aux températures él...

Страница 32: ...rojetés vers des personnes et qu ils ne puissent pénétrer dans un bâtiment ou susciter l échauffement de matériaux combustibles voir Fig 2 a La bouche de décharge du circuit de décharge avec ventilateur doit être placée à au moins 7 pi 213 cm au dessus du sol dans le cas où il s agirait d une voie de circulation de piétons accessible au public b La bouche de décharge doit être située à au moins 3 ...

Страница 33: ...érence utiliser des sections rectilignes aussi longues que possible pour minimiser le nombre de jointures 5 Assurer une parfaite étanchéité de chaque jointure du circuit de décharge entre le chauffe eau Bosch et la bouche de décharge avec un matériau de silicones très résistant aux températures élevées et ou du ruban d aluminium résistant aux températures élevées conformément aux instructions du f...

Страница 34: ... la fumée ou la flamme de l allumette sera aspirée vers le bord supérieur du capot du chauffe eau Bosch et dans l ouverture ou la hotte d aspiration Voir l illustration Contrôle du tirage NOTE Si la fumée ou la flamme n est pas aspirée ceci indique que des gaz de combustion s échappent dans la pièce par les ouvertures il ne faut alors pas faire fonctionner le chauffe eau avant que les réglages ou ...

Страница 35: ...angère du circuit de décharge 3 Système de sécurité Pour vérifier le bon fonctionnement du système de sécurité obstruer temporairement la bouche de décharge et observer l effet produit le système doit interrompre l alimentation en gaz du chauffe eau 4 Contrôle du tirage Rechercher d éventuelles fuites de gaz de combustion voir le processus décrit à la page 9 à la section Utilisation et contrôle du...

Страница 36: ...e chauffe eau instantané BOSCH est fourni avec deux raccords S qu on doit installer sur les connexions d entrée et de sortie de la vanne manométrique voir la figure 4 ci dessous Figure 4 Les raccords S comportent un filetage de connexion po NPT norme américaine pour tuyauterie La canalisation d arrivée d eau froide devra être raccordée au raccord S connecté à l entrée du chauffe eau et la canalisa...

Страница 37: ...agit de composants du système d alimentation en gaz et non pas de composants du chauffe eau Une obstruction des évents peut survenir par temps de gel glace Figure 7 Point de test D du brûleur pour la mesure de la pression d alimentation du brûleur au débit maximum pression mesurée en colonne d eau Altitude standard 4 58 po gaz naturel ou 9 11 po propane Altitude élevée 3 73 po gaz naturel ou 7 27 ...

Страница 38: ...de de construction ou de rénovation du bâtiment et a été exposé à une quantité excessive de poussière on doit inspecter et nettoyer régulièrement l échangeur de chaleur La présence de poussière entre les ailettes de l échangeur de chaleur durant le fonctionnement peut susciter un risque pour la santé Demander immédiatement à un technicien qualifié d inspecter l appareil et de remplacer tout compos...

Страница 39: ...oir ci dessous Déterminer lors de l installation pour quelle pression de gaz le détendeur est réglé pour vérifier que cette pression convient pour le gaz disponible et pour l altitude à laquelle l appareil est utilisé Pour le réglage correct voir la plaque signalétique de l appareil et le Tableau 1 ci dessous Au Canada pour un chauffe eau installé à une altitude standard 0 à 2000 pi au dessus du n...

Страница 40: ...e nouveau puiser de l eau chaude Dans le cas d une mise en sécurité répétée Demander I intervention d un professionnel qualifié pour contrôler le bon fonctionnement de I appareil et vérifier la vacuité des conduits d évacuation Toute intervention sur I appareil devra être effectuée par du personnel qualifié Maintenance enlever la vis de fixation du dispositif de contrôle d évacuation de gaz brûles...

Страница 41: ...age d eau chaude pour permettre l évacuation progressive de l air piégé dans la canalisation de gaz Pas de production d étincelles lorsque l eau circule 1 Fermer le robinet de puisage 2 Ôter le bouton de protection et dévisser la vis de réglage jusqu au point où le dispositif produit des étincelles 3 Revisser de 1 5 tour 4 Réinstaller le bouchon de protection Production constante d étincelles en l...

Страница 42: ... le réservoir pressurisé associé à la pompe d alimentation n est pas excessivement rempli d air 6 Inspecter le ventilateur Le ventilateur doit fonctionner lorsque le brûleur s allume 7 Inspecter le clapet de la bouche de décharge à l extérieur peut il manœuvrer librement Fig 14 Schéma des circuits électriques 7 interrupteur à diaphragme 8 sonde d ionisation 9 fusible 10 électrode de la veilleuse 1...

Страница 43: ...age Faire tourner le bouton de réglage de la température dans le sens horaire vers la droite Note Ceci suscite une diminution du débit d activation du chauffe eau 2 Débit d eau excessif à travers le chauffe eau compte tenu de sa puissance thermique La pression d alimentation du chauffe eau peut être trop élevée 60 lb po maximum pour l obtention des meilleurs résultats ou bien il y a eu une érosion...

Страница 44: ...al 5 Tube d alimentation de la flamme de veille 6 Vanne d admission de gaz 5 11 1 4 9 10 12 2 6 8 7 13 3 Voir fig 7 page 13 Voir le tableau 1 page 15 7 Module de commande électronique 8 Cordon d alimentation 9 Commutateur marche arrêt 10 Bouton de réglage de la température 11 Micro contacteur 12 Connecteur pour manomètre canalisation 13 Ventilateur d extraction ...

Страница 45: ...21 6 720 606 599 ...

Страница 46: ... 8 700 707 349 14 Joint 8 700 103 173 15 Bloc gaz 8 707 021 069 GN 15 Bloc gaz 8 707 021 068 GPL 16 Membrane rupteur 8 708 504 021 GN 16 Membrane rupteur 8 708 504 049 GPL 17 Tête magnétique d allumage 8 708 501 249 18 Servovalve 8 708 501 250 19 Tube arrivée eau 8 700 705 627 20 Ventilateur 8 707 204 023 21 Câble 8 704 401 168 22 Tube eau chaude 8 700 715 080 23 Limiteur de température 8 707 206 ...

Страница 47: ...23 6 720 606 599 Fig 19 COMPOSANTS INTERNES ET LISTE DES PIÈCES ...

Страница 48: ......

Отзывы: