Installing the facing panels
6 720 613 057 (2006/04)
36
10.2 Side facing panels
B
Place the edge of the right and left side facing panels
(Fig. 47, Item 1) up into the recessed grip on the col-
lector and push in over the lower facing panel.
B
Press the fold overlap on both panels together to fix
in place (Fig. 47, Item 3).
The side facing panels must be fastened to the roof bat-
tens using three clips on each side, right and left
(two clips for landscape version).
B
Insert clip (Fig. 48, Item 1) into the edge of the side
facing panel.
B
Push clip with facing panel towards collector, so that
the facing panel is pressed against the collector.
B
Fasten clip with nail provided.
10.3 Middle cover strip between two collectors
The middle cover strip seals the gap between two collec-
tors.
B
Press cover strip (Fig. 49, Item 1) with the folded
edge facing downwards into the gap between the two
collectors and make sure it is centrally positioned.
B
Using size 8 spanner, tighten screws (Fig. 49,
Item 2) by hand, beginning at the bottom.
The profile is clamped to the collector frame.
Fig. 47
Fitting the side facing panel on the right
63043975.13-1.SD
63043975.13-1.SD
3.
1
2
3
CAUTION!
BUILDING DAMAGE
from leaks in the roof.
B
Place the mounting plates (Fig. 47,
Item 2) into the lower edge of the col-
lector.
Fig. 48
Securing side facing panel
63043975.14-1.SD
63043975.14-1.SD
1
Fig. 49
Middle cover strip
63043975.16-1.SD
63043975.16-1.SD
1
2