INSTALLATION
6 720 644 842b (2010/12)
24
7.5
EXTENDED PLUME MANAGEMENT INSTALLATION FOR A BALCONY / OVERHANG
1. Refer to figure 36 and remove and retain the screws
and terminal end.
2. Fit the terminal bend to the terminal outlet and secure
with the screws removed earlier.
3. If required, rotate the terminal bend for angled fluing.
1. Refer to figure 42 and mark the position for the wall
clamp that coincides with the extension tube just
below the top fitting.
Drill a suitable hole and fit the wall plug.
Screw the clamp into the wall plug as shown.
2. Push the extension tube fully into the terminal bend,
then withdraw the tube by approximately 10mm to
allow for expansion.
3. Secure the extension to the wall with the clamp and
screws provided.
B
Mount the other extension tubes as before and secure
to the wall.
4. Remove the screw from the terminal end and remove
the grill.
5. Drill a hole through the plume outlet end and secure
the grill in place.
Fig. 42 Under balcony installation
To ease assembly of the flue components,
lightly grease the seals with the solvent-free
grease supplied.
Check all the seals are properly seated in
the grooves provided and are in good
condition.
All flue joints must be sealed to prevent
leakage of condensate and flue products.
NOTE:
DO NOT ROTATE THE COMPLETE
FLUE TERMINAL ASSEMBLY.
B
The flue terminal outlet has built-in stops
to limit rotation for horizontal fluing to
allow condensate to run back to the
boiler for safe disposal.
Do not attempt to force beyond the limit
stops.
Ensure that the plume outlet, projects at
least 100mmpassed the balcony/overhang.
100 mm
6720644842-26.1Wo
1.
1.
2.
2.
2.
3.
3.
5.
4.
3.
65 mm
1.
10 mm
2.