ELECTRICAL
i System Diverter Valve kit 6 720 645 222 (2012/09)
10
OPTIONAL EXTERNAL FROST STAT CONNECTION ST6
Fig. 21 Frost Thermostat
▶ Connect frost thermostat cables to terminals F
S
& F
R
.
▶ These are not polarity sensitive.
CONNECTOR LOCATIONS
Fig. 22 Connector locations
S11
Fuse F1 2.5A
ST6
Frost thermostat connection
ST8
Optional cylinder stat
ST10
Mains in & external controls connections
ST18
Code plug
ST19
EMS BUS connection
NOTICE: RESET THE CONTROL BOARD
Following changes to the wiring of ST15 and ST8 the
control board will need to be reset to recognise the new
connection.
The power must be on to reset, all lights will flash to
confirm reset.
To reset the control board:
▶ Hold the Service mode “Spanner” and the Eco buttons
down for at least five seconds.
Frost Thermostat
FS
FR
NP LP
ST6
6720643895-43.1Wo
6720804530-03.2W
o
S11
ST10
ST6
ST8
ST19
ST18