en
Faults and what to do about them
44
:
Warning
Risk of injury!
Reaching into the drum while it is still
turning may cause hand injuries.
Do not reach into the drum when it is
turning.
Wait until the drum has stopped turning.
Caution!
Water damage!
Any escaping water may cause water
damage.
Do not open the door if water can be
seen through the glass.
1.
Turn the programme selector to
Off
.
Pull out the mains plug.
2.
Open the service flap.
3.
4.
Pull the emergency release
downwards with a tool and release.
The door can then be opened.
Information on the display panel
Display
Cause/Remedy
Õ
■
Flashes fast + signal
: The door was opened and the water level is too high.
Close the door, continue the programme with
A
Start/Reload button or
select
[
Drain
.
■
Flashes slowly
: The door lock temperature is too high to open the door. Wait
approx. 30 seconds until the door lock temperature cools down.
Hot
The door cannot be opened after the drying programme due to the high tempera-
ture. The cooling process continues until the temperature in the drum has dropped.
r
■
Flashes
(no water supply): Water tap turned on? Filter in the water supply is
blocked?
"Filter in the water supply is blocked" on page 43
Is the supply hose kinked or trapped?
■
Lights up
(low water pressure): For information only. This will not affect the
programme progress. The programme duration is extended.
E
lights up
The childproof lock is activated – deactivate it.