Fault
Cause and troubleshooting
The door cannot
be opened.
▶
"Cancelling the programme", Page 38
Water level is too high.
▶
Start the
Drain
programme.
Power failure.
▶
Open the door using the emergency release.
→
The water is not drain-
ing.
Drain pipe or water outlet hose is blocked.
▶
Clean the drain pipe and the water outlet hose.
Drain pipe or water drain hose is caught or jammed.
▶
Ensure that the drain pipe and water drain hose are
not kinked or trapped.
Drain pump is blocked.
▶
"Cleaning the drain pump", Page 47
is activated.
▶
Continue the programme by selecting
Spin
or
Drain
and pressing
Start/Reload
.
"Resuming the programme when the programme
status is Rinse Hold", Page 38
The water outlet hose is connected too high.
▶
Install the water outlet hose at a maximum height of
1 metre.
Pump cover is not correctly assembled.
▶
Correctly assemble the pump cover.
Detergent dosage is too high.
▶
Immediate measure: Mix one tablespoon of fabric
softener with 0.5 litres of water and pour the mix-
ture into the left-hand compartment (not for outdoor
clothing, sportswear or items stuffed with down).
▶
Reduce the amount of detergent for the next wash-
ing cycle with the same load.
Unapproved extension installed on the water drain
hose.
▶
Remove any unapproved extensions from the water
hose. Connecting the appliance
Water is not flowing
in. Detergent is not
being dispensed.
You have not pressed
Start/Reload
.
▶
Press
Start/Reload
.
The filter in the water inflow is blocked.
▶
Clean the water inflow filter →
The tap is turned off.