Bosch Security Systems | 2004-06
EN
| 9
7902 - 7905
| Installation and Operational Manual
Adjust lens position (0°, -5° or -10°) according to desired maximum
sensor range (see table below).
Remark:
Do not use pos5° or +10° as they do not apply to
this PIR.
7. Make the interconnections between the PIR and the alarm/action
box with the cable supplied (see figure below).
Sensor height
Maximum sensor range (m) / Lens position (°)
0°
-5°
-10°
2.5 m
14 m
12.5 m
11 m
2.0 m
12 m
10.5 m
9.5 m
1.5 m
10 m
8.5 m
8 m
1
2
3
4
5
6
7
8
Terminal block (for interconnection with alarm/action box)
Lens position (sensor range adjustment)
Jumper (walk test LED activated/deactivated)
Tamper switch
PYRO sensor
Jumper (1, 2 or 3 pulse count)
Locking latch
Terminal block in alarm/action box
5
8
7
6
2
1
4
3
GND
NC
+12V
+10
+5
0
-5
-10
+
_
NC
PIR