Error Code Description
Cause/Notes
Suggested Action(s)
E000
Wrong module code
(E100/E400 internal errors
reported as E000)
Control module and user interface are
mismatched. No operation is possible.
Enter correct option code in Service mode.
E302
Control module too hot
Temperature sensor on the control module
detects temperature higher than limit value.
Control turns off heating elements and fan
defaults to high speed. When cavity
temperature lowers to 212°F/100°C, heating
will resume and error will be cleared. (If self-
clean was running, it will be disabled until a
control reset is performed.)
If cooling fan is
not
operating…
Check connections to the fan and the
control module (see Small Load Schematic).
If cooling fan
is
operating…
Check element operation
Check for air obstruction or damaged
upper/lower ventilation trims
Check for stuck relays.