8.3
Malfunctions with iSCSI Connections
Malfunction
Possible causes
Recommended solution
After connecting to the
iSCSI destination, no
LUNs are displayed.
Incorrect LUN mapping during
iSCSI system configuration.
Check the iSCSI system
configuration and reconnect.
After connecting to the
iSCSI destination, "LUN
FAIL" appears below a
node.
The LUN list could not be read,
as it was assigned to the wrong
network interface.
Check the iSCSI system
configuration and reconnect.
LUN mapping is not
possible.
Some iSCSI systems do not
support the use of an initiator
extension.
Delete the initiator extension on
the
iSCSI
configuration page.