High Speed Pan/Tilt System
Configuring the System | en
45
Bosch Security Systems
Instruction Manual
F01U.073.990 | Version 1.0 | 2007.07
Special Preset Parameters
The
Special Preset Parameters
menu can be used to make parameter settings. Increase the
default value to increase the speed between presets or the scan speed.
SPECIAL PRESET PARAMETER MENU
1 - PRESET SPEED REF.
: 20.0
2 - SCAN SPEED
: 20.0
3 - TILT SPEED
REDUCTION
: 100
6 - FIRST DWELL
TIME
00005
7 - FORCE PRST
DW.TIME
NO
8 - FORCE PRST
SPEED
NO
Feature
Description
Default
Options
PRESET SPEED REF.
Default value whenever a preset
position is stored.
20.0
0.1 - 100.0
SCAN SPEED
Reference speed used when a pre-
set position is recalled by the scan
function.
20.0
0.1 - 100.0
TILT SPEED REDUCTION
Tilt speed reducing factor with
respect to pan speed.
100.0
0.1 - 100.0
FIRST DWELL TIME
Time in seconds to dwell at preset
position.
00005
00001 - 01000
FORCE PRST DW.TIME
Forces the default dwell time value
for all presets.
NO
YES, NO
FORCE PRST SPEED
Forces the default speed value for
all presets.
NO
YES, NO