Solution Ultima RF Receiver Interface Connections
Figure 1: RF Receiver (RF3212) Wiring Diagram
Wiring and Power Up
Operation
- Remove power from the control panel.
The following describes the status of the module based on the LED
condition.
- Connect the RF Receiver to the control panel as shown
above using 0.8mm (22-gauge) or larger wire. Wire length
should not exceed 300 meters (1000 feet).
LED On
– Module is functioning normally.
LED Off
– Power failure has occurred or module is not wired
correctly.
- Apply power to the control panel. The red LED at the centre
of the module will turn on.
LED Turns Off Momentarily
– Module acknowledged receiving an
RF signal from a remote RF device.
RF Keyfob Operations For Solution Ultima Series Control Panels
Figure 2: RF3332 - 2 Button RF Keyfob
Figure 3: RF3332 - 2 Button RF Keyfob
Solution Ultima 862
Quick Reference Guide
19
Electronics Design and Manufacturing Pty LimitedSOL ULTIMA 862 QUICK REF GUIDE.D