Solution Ultima 862 

Quick Reference Guide 

 

 

ISSUE 1.70

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание Ultima 862

Страница 1: ...Solution Ultima 862 Quick Reference Guide ISSUE 1 70 ...

Страница 2: ...may have been used Rather than put a trademark symbol in every occurrence of a trademark name we state that we are using the names only in an editorial fashion and to the benefit of the trademark owner with no intention of infringement of the trademark Notice of Liability While every precaution has been taken in the preparation of this document neither Bosch Security Systems Pty Limited nor any of...

Страница 3: ... LOCATION 000 First location of the Primary Telephone Number To move to another programming location enter the location number followed by the key The data in the new location will now be displayed via the codepad indicators eg If you entered 34 the system will jump you to LOCATION 034 the beginning of the Subscriber ID Number For Receiver 1 To move to the next location press the key This will ste...

Страница 4: ...Option Description 1 Dialler Reporting Functions Allowed 2 Remote Arming Via Telephone Allowed 4 Answering Machine Bypass Only When Armed 8 Use Bell 103 For FSK Format Disabled CCITT V21 Installer s Programming Commands These commands can only be used when you enter Installer s Programming Mode Enter the command followed by the key Command Description 958 Enable Disable Zone Status Hand Held Progr...

Страница 5: ...o isolate followed by the key Repeat step 2 if more than one zone is required to be isolated 3 Press the key to exit when finished Code To Isolate 1 Press the key once 2 Enter your user code followed by the key 3 Enter the zone number that you want to isolate followed by the key Repeat step 2 if more than one zone is required to be isolated 4 Press the key to exit when finished Add Delete RF Devic...

Страница 6: ...ed by the key Add RF Keyfob 1 Enter the Master Code followed by 1 and the key eg 2580 1 2 Enter the User Number 9 16 that you want to add followed by the key 3 Enter the 9 digit RF keyfob ID number followed by the key Delete A User Code RF Keyfob 1 Enter the Master Code followed by 1 and the key eg 2580 1 2 Enter the User Number 1 16 that you want to delete followed by the key 3 Press the key to d...

Страница 7: ...ermine Fault 6 Communication Fail 1 Receiver 1 Fail Dialler 2 Receiver 2 Fail Dialler Modem Call Alarm Link 1 Press and hold the 6 key until two beeps are heard Latching Outputs Reset 1 Press and hold the 7 key until two beeps are heard Codepad Buzzer Tone 1 Press and hold the 8 key until the desired buzzer tone has been reached 2 Press the key to exit Test Report 1 Press and hold the 9 key until ...

Страница 8: ... 0 0 0 0 0 0 0 0 0 0 0 0 0 1 HI LO Handshake Contact ID 4 No Handshake 2 1400 Hz Ademco TX 1900 Hz 5 Pager 3 2300 Hz Sescoa TX 1800 Hz 1 1 Contact ID 4 Domestic 7 Reserved 2 4 2 Expressed 5 Basic Pager 8 4 2 Pulsed 3 FSK 300 Baud 6 Reserved 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 HI LO Handshake Contact ID 4 No Handshake 2 1400 Hz Ademco TX 1900 Hz 5 Pager 3...

Страница 9: ...vel Authority Level Description 0 Arm Disarm 1 Arm Only 2 Arm Disarm Open Close Reports 3 Arm Only Close Reports 4 Arm Disarm Code Required To Isolate 6 Arm Disarm Open Close Reports Code Required To Isolate 8 Master Code Arm Disarm 10 Master Code Arm Disarm Open Close Reports 12 Master Code Arm Disarm Code Required To Isolate 14 Master Code Arm Disarm Code Required To Isolate Open Close Reports 9...

Страница 10: ... 296 297 298 299 300 301 Zone 05 0 0 0 1 14 1 1 Default Instant Zone Type Zone Pulse Count Zone Pulse Count Time Zone Options 1 Zone Options 2 Report Code Dialler Options Location 302 303 304 305 306 307 308 Zone 06 0 0 0 1 14 1 1 Default Instant Zone Type Zone Pulse Count Zone Pulse Count Time Zone Options 1 Zone Options 2 Report Code Dialler Options Location 309 310 311 312 313 314 315 Zone 07 1...

Страница 11: ...t 2 Zone Isolation Allowed 4 Silent Alarm 4 Forced Arming Allowed 8 Sensor Watch 8 Zone Restore Report Allowed Zone Dialler Options Option Group 0 No Zone Reports Allowed 1 Report To Receiver 1 2 Report To Receiver 2 4 Report To Both Receiver 1 Receiver 2 8 Report To Receiver 2 Only If Receiver 1 Fails Keyswitch Zone Options The keyswitch zone options replace Zone Options 1 only for the zones that...

Страница 12: ...ne Bypass Restore Report Location 331 Zone Trouble Report Location 332 Zone Trouble Restore Report 2 3 4 5 Location 333 Sensor Watch Report Location 334 Sensor Watch Restore Report 14 1 0 No Zone Status Reports Allowed 1 Report To Receiver 1 2 Report To Receiver 2 4 Report To Both Receiver 1 Receiver 2 8 Report To Receiver 2 Only If Receiver 1 Fails 0 Location 337 Increments Of 6 Hours 0 90 Hours ...

Страница 13: ...ation 356 Tens Digit Location 357 Units Digit 10 8 Location 358 Tens Digit Location 359 Units Digit 10 2 Location 360 Tens Digit Location 361 Units Digit 10 7 Location 362 Tens Digit Location 363 Units Digit 10 1 Location 364 Tens Digit Location 365 Units Digit 10 6 Location 366 Tens Digit Location 367 Units Digit 368 369 370 6 7 12 Location 368 Code Retry Limit 0 Unlimited Location 369 Tens Digit...

Страница 14: ...larm Enabled 4 1 Reserved 1 1 Telephone Line Fail 4 2 Reserved 1 2 Kiss Off Received 4 3 Reserved 1 3 Fuse Fail 4 4 Reserved 1 4 AC Fail 4 5 Chime 1 5 Low Battery 4 6 Zone Not Sealed 1 6 Horn Speaker Fail 4 7 Zone Not Sealed After Exit Time 1 7 Sensor Watch Alarm 4 8 Reserved 1 8 Codepad Medical Alarm 4 9 AC Mains Cycle 60 Hz Or 50 Hz 1 9 Codepad Fire Alarm 4 10 Area 1 Zone Unsealed Solution 880 O...

Страница 15: ...se x the multiplier eg If you want the output to pulse one 1 second ON and five 5 seconds OFF you would program time base as one 1 and the multiplier as five 5 Solution Ultima 862 Quick Reference Guide 15 SOL ULTIMA 862 QUICK REF GUIDE Polarity Modes Option Description Option Description 0 Disabled 1 Normally Open Going Low 8 Normally Low Going Open 2 Normally Open Pulsing Low 9 Normally Low Pulsi...

Страница 16: ... Increments Of 16 Seconds 0 240 Seconds 0 0 Location 420 Increments Of Days Tens Digit Location 421 Increments Of Days Units Digit 0 0 0 Location 422 Increments Of 10 Seconds 0 150 Seconds 5 Location 423 Increments Of 1 Minute 0 15 Minutes 7 Location 424 0 Slowest Frequency 15 Fastest Frequency 1 Location 425 Increments of 5 Minutes 0 75 Minutes Location 426 Hour Of The Day Tens Digit Location 427...

Страница 17: ... 1 2 8 Zone Tamper Alarms To Be Silent 5 0 1 DS 304Mhz RF Receiver RF3212 2 Latching Keyswitch Input 3 Momentary Keyswitch Input 4 Reserved 0 0 1 Sound Siren On RF Receiver Fail 2 Sound Siren On RF Receiver Tamper Jamming 4 Unseal Zone That Fails Supervision If Supervision Enabled 8 RF Jamming Monitoring Allowed Location 528 Map RF Device 1 To Zone 1 To 8 Location 529 Map RF Device 2 To Zone 1 To ...

Страница 18: ...tion 812 Signal Strength For RF Device 12 Location 813 Signal Strength For RF Device 13 Location 814 Signal Strength For RF Device 14 Location 815 Signal Strength For RF Device 15 Location 816 Signal Strength For RF Device 16 809 810 811 812 813 814 815 816 0 0 0 0 0 0 0 0 D9 D10 D11 D12 D13 D14 D15 D16 0 0 Defaulting System Allowed 15 Defaulting System Disabled Location 901 Hour Of The Day Tens D...

Страница 19: ...00 meters 1000 feet LED On Module is functioning normally LED Off Power failure has occurred or module is not wired correctly Apply power to the control panel The red LED at the centre of the module will turn on LED Turns Off Momentarily Module acknowledged receiving an RF signal from a remote RF device RF Keyfob Operations For Solution Ultima Series Control Panels Figure 2 RF3332 2 Button RF Keyf...

Страница 20: ...EOL Wiring Diagram With Tamper Location 266 14 Connections For Split EOL Resistors Using N O Contacts Figure 6 Split EOL Wiring Diagrams Using N O Contacts Wiring Diagram For Keyswitch Zone Figure 7 Wiring Diagram For Keyswitch Zone 20 Solution Ultima 862 Quick Reference Guide SOL ULTIMA 862 QUICK REF GUIDE DOCBosch Security Systems Pty Limited ...

Страница 21: ...Wiring Diagram Figure 8 Solution Ultima Series Wiring Diagram Solution Ultima 862 Quick Reference Guide 21 Electronics Design and Manufacturing Pty LimitedSOL ULTIMA 862 QUICK REF GUIDE D ...

Страница 22: ...Component Overlay Figure 9 Solution Ultima Series Component Overlay 22 Solution Ultima 862 Quick Reference Guide SOL ULTIMA 862 QUICK REF GUIDE DOCBosch Security Systems Pty Limited ...

Страница 23: ......