background image

2/11

DS950 Series Installation Instructions

P/N: F01U068629-13     Page 4

© 2011 Bosch Security Systems, Inc.
130 Perinton Parkway, Fairport, New York 14450
www.boschsecurity.com

8.2

Microwave Meter Readings

Connect the meter to the Microwave (

μ

w) Noise Voltage Pins.

With no target motion in the pattern, read the voltage. The
background noise voltage should be steady, and should not
exceed 0.75 VDC. If it does, the cause of the disturbance should
be found and eliminated.

NOTE

:

Remember that microwaves penetrate non-metallic
surfaces. Movement on the other side of walls and doors
viewed by the detector could cause unexpected background
noise readings.

9.0

Supervision Features

The supervision features function as follows:

PIR / Microwave

:  The complete circuit operation of these

subsystems is checked approximately every 12 hours. If the PIR
or microwave subsystems fail, the tri-color LED will flash red
four times per cycle and the unit should be replaced.

Default

:  If the microwave subsystem fails, the detector will default

to PIR technology protection. The PIR signal sensitivity will
automatically change from INT to STD.

Trouble Clear

:  An intrusion alarm will reset most existing

supervision trouble conditions. There must be at least ten
seconds of no activity (no alarm) prior to the detector alarm. Self
Test failures will not be cleared; the detector must be replaced.

Anti-masking

:  When enabled, the detector will indicate an Anti-

mask supervision trouble condition if a microwave reflective
material (e.g. metal, most plastics, etc.) is placed within one foot
of the detector. This feature can be used to prevent intentional
and accidental masking of the face of the detector. It is enabled
or disabled using the Motion Monitor and Anti-mask Pins.

NOTE

:

The anti-masking feature may interpret removal and/or
replacement of the cover as an attempt to mask the detector
and may signal a supervision trouble condition. If this should
occur, reset the detector by removing and then re-applying
its power. The trouble condition will also be reset by the next
detector alarm after a 10 second period of no alarms from
either technology.

Motion Monitor Supervision

:  This feature verifies that each

technology has a clear view of the detection area. When selected,
a supervision timer is activated which gives the detector the ability
to indicate a supervision trouble condition if the time selected by
the pins has elapsed since the last detector alarm.

If the detector does not see a detector alarm within the selected

time period, the tri-color LED will flash red two times to indicate
a supervision trouble condition and the Trouble output will
activate.

If the detector is set for 1-day motion monitor supervision, the motion

monitor timer is only active when there is no voltage applied to
terminal 8 of the detector. See Section 7.0.

10.0 Maintenance

At least once a year, the range and coverage should be verified. To
ensure continual daily operation, the end user should be instructed
to walk through the far end of the coverage pattern. This ensures an
alarm output prior to arming the system.

11.0 Coverage Pattern

The DS950 has a standard broad coverage pattern or an optional
long-range coverage pattern. The protected coverage area is where
the microwave and PIR patterns overlap.

An optional Look Down lens is located under the detector. 

This

lens must be unmasked before it is operational.  Use caution to
remove the black mask only. Do not attempt to remove the white
lens assembly.

 The Look Down lens is 

not recommended

 for

installations containing pets or small animals. The Look Down
zone is shown in black on the Coverage Pattern drawings.

Standard Broad Coverage

0

0

3

6

9

-5°

SIDE VIEW

A-I

J-M

N-P

Q,R

3

Look-Down

12

15

10

20

30

40

50

2.3

0

10

7.5

0

Meters

Feet

0

3

6

9

0

3

6

9

3

6

9

TOP VIEW

0

10

20

30

40

50

12

15

Meters

30

20

10

0

Feet

10

20

30

B

A

C

D

G

H

I

J

K

L

M

N

O

P

E

F

R

Q

Long Range Barrier Coverage

Meters

30

0

Feet

100

0

5

5

TOP VIEW

10

20

30

40

50

60

70

80

90

3

6

9

12

15

18

21

24

27

0

0

1.5

1.5

A

B

C

D

Meters

30

0

Feet

100

0

10

SIDE VIEW

10

20

30

40

50

60

70

80

90

3

6

9

12

15

18

21

24

27

0

-3°

3 Meters

A

B

C

D

7.5

2.3

Look-Down

11.1 Pattern Masking

The PIR coverage pattern may be masked using masking tape or
electrical tape on the inside (grooved side) of the lens to cover the
appropriate pattern areas as shown in the following illustrations.
Always walk test for the desired coverage after masking.

A B C D E F G H I

N J Q K O L R M P

DS950 Standard Lens

A

B
C

D

Optional Long Range

Barrier Lens

NOTE:

Masking only eliminates the PIR portion of the coverage
and has no effect on the microwave pattern.

Содержание TriTech DS950 Series

Страница 1: ...ding interference that may cause undesirable operation Changes or modifications not expressly approved by Bosch Security Systems can void the user s authority to operate the equipment 2 0 Installation Considerations NOTE The DS950 is not recommended for installations containing pets or small animals Use the DS820 or DS835 for such installations Never install the detector in an environment that cau...

Страница 2: ...n of the tri color LED If LED indication is not desired after setup and walk tests are completed place in the OFF position The OFF position does not prevent the LED from indicating supervision trouble conditions 6 2 Memory Operation and Microwave Inhibit To use the alarm memory function cut the Memory Jumper after walk testing When this jumper is cut the Microwave Inhibit function is also activate...

Страница 3: ...e pattern downward Tighten the screw snug when positioning is completed 7 2 Establishing Microwave Coverage NOTE It is important to wait one minute after removing replacing the cover so the microwave portion of the detector can settle and to wait at least ten seconds between the following walk testing procedures The tri color LED should be OFF before walk testing Walk test across the pattern at th...

Страница 4: ...the detection area When selected a supervision timer is activated which gives the detector the ability to indicate a supervision trouble condition if the time selected by the pins has elapsed since the last detector alarm If the detector does not see a detector alarm within the selected time period the tri color LED will flash red two times to indicate a supervision trouble condition and the Troub...

Отзывы: