TR5500T – 6 720 875 993 (2017/12)
18
In case of fault
(*) the third LED indicates whether or not the off-peak contact was
correctly installed.
Third LED “
on
” if off-peak contact on.
Third LED “
off
” if off-peak contact out.
If the third LED is off during the off-peak period, the fault lies in the
installation of the off-peak contacts.
When installing the device without off-peak contact, the third LED is
always on.
Note
In an “
error condition
”, the device is out of order.
In the case of an “
anode fault
” or a “
potentiometer fault
”, the device
can be manually activated for a heating cycle by pressing the “fast-
heating” button
. In this case the device heats until a water
temperature of 40°C is reached. The device heats at the installed power
for single-power and boiler mode connections, for double-power
connections it heats according to the basic load of the connection, at
1kW, 2kW or 3kW.
If the fault could not be remedied, please contact the customer
service operators.
Note
When the device is full with water and functions normally (there are no
faults apparent), the device cannot be separated from the mains
voltage, otherwise the external power source anode stops functioning
and the device rusts through. For complaints of this nature, the warranty
and guarantee do not apply.
After the assembly, please present the user with the instructions for
use and explain the device to them.
Display (LED) Status
Heat content display
indicators (LED)
Cause / Fault
Solution
Who
Anode Service
Fast
Heating
1
2
3
4
5
6
On
Flashing
Off
On
On
See
below
(*)
–
On
On
Internal
electronic failure
Electronic board locked, wait 15mins and then reset
Techni-
cian
On
Flashing
Off
On
–
See
below
(*)
–
–
On
The reservoir has
heated without
water
Turn the device off, check the cause of the water
shortage (leakage, faulty water connection).
If the problem remains contact technician
Techni-
cian
On
Flashing
Off
On
–
See
below
(*)
–
On
–
Water
temperature in
reservoir too hot
Reset, wait until the reservoir has cooled.
If the problem remains please contact technician
Techni-
cian
On
Flashing
Off
On
–
See
below
(*)
On
–
–
Internal
electronic failure
Reset, if the problem remains please contact
technician
Techni-
cian
On
Flashing
Off
–
On
See
below
(*)
On
–
–
Internal
electronic failure
Reset, if the problem remains please contact
technician
Techni-
cian
On
Flashing
Off
On
–
See
below
(*)
–
–
–
Temperature
sensor fault
Reset, if the problem remains please contact
technician
Techni-
cian
On
Flashing
Off
On
On
See
below
(*)
–
–
–
Temperature fault
between heating/
sensor
Reset, if the problem remains please contact
technician
Techni-
cian
Off
Flashing
Off
–
–
See
below
(*)
On
–
–
Anode fault
Check that the reservoir is filled. If the problem
remains please contact technician
Techni-
cian
On
Flashing Flashing
–
–
See
below
(*)
–
–
–
Temperature
selector fault
Reset not possible, please contact technician
Techni-
cian
Содержание TR5500T 100
Страница 21: ...For Users and Technicians TR5500T 6 720 875 993 2017 12 21 3 4 5 ...
Страница 23: ...For Users and Technicians TR5500T 6 720 875 993 2017 12 23 8 9 TR5500T 80 100 TR5500T 120 150 ...
Страница 24: ...TR5500T 6 720 875 993 2017 12 24 For Users and Technicians 10 11 12 ...
Страница 25: ...For Users and Technicians TR5500T 6 720 875 993 2017 12 25 13 TR5500T ...
Страница 28: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com 6720875993 ...