Troubleshooting
aus
43
Fault
Cause and troubleshooting
E:32-00 will light up
alternately or indicator
for water supply lights
up.
The filters in the water connection of the supply or
AquaStop hose are blocked.
1.
Switch off the appliance.
2.
Pull out the mains plug.
3.
Turn off the water tap.
4.
Unscrew the water connection.
5.
Remove the filter from the supply hose
6.
Clean the filter.
7.
Re-insert the filter in the supply hose.
8.
Screw the water connection back on.
9.
Check the water connection for leaks.
10.
Restore the power supply.
11.
Switch the appliance on.
E:34-00 will light up
alternately.
Water is continuously running into the appliance.
1.
Turn off the water tap.
2.
Call Customer Service →
E:61-03 will light up
alternately. Water is
not drained.
Wastewater hose is blocked or kinked.
1.
Reposition the wastewater hose without kinks.
2.
Remove residues.
Siphon connection is still sealed.
▶
Check the connection to the siphon and open if ne-
cessary.
Cover of the wastewater pump is loose.
▶
Secure the cover of the Wastewater pump
→
E:61-02 will light up
alternately.
Wastewater pump is blocked.
▶
Clean the wastewater pump.
→
"Clean wastewater pump", Page 54
Cover of the wastewater pump is loose
▶