Troubleshooting
aus
45
Fault
Cause
Troubleshooting
E:61-02 will light up altern-
ately.
Cover of the wastewater
pump is loose
▶
Secure the cover of the "Wastewa-
ter pump "
into position.
E:90-01 will light up altern-
ately.
Mains voltage is too low.
This is not a fault on the appliance.
1.
Contact an electrician.
2.
Have the mains voltage and elec-
trical installation checked by an
electrician.
A different error code ap-
pears in the display window.
E:01-00 to E:90-10
A technical fault is present.
1.
Press .
2.
Unplug the appliance or switch off
the fuse.
3.
Wait at least 2 minutes.
4.
Insert the mains plug of the appli-
ance in a socket or switch on the
fuse.
5.
Switch the appliance on.
6.
If the problem occurs again:
‒
Press .
‒
Turn off the water tap.
‒
Pull out the mains plug.
‒
ror code.
Washing results
Fault
Cause
Troubleshooting
Tableware is not dry.
No rinse aid used or dosage
set too low.
1.
2.
Set the amount of rinse aid to be
dispensed.
"Setting the amount of rinse aid",
Programme or programme
option has no drying phase,
or the drying phase is too
brief.
▶
Select a programme with drying,
e.g. intensive, strong or ECO pro-
gramme.
Some option buttons decrease the
drying result, e.g varioSpeed.