(1) Preassembled tool holder
(2) Knurled screw
5. Position the mount for the line laser
(1)
with the
holes over the tube connectors on the guide tubes.
1
22
3
4
5
4 Nm
(1) Line laser mount
(2) Tube connectors on guide tubes
(3) Countersunk screw
(4) Washer
(5) Hex nut
6. Use the countersunk screws
(3),
washers
(4)
and
hex nuts
(5)
to secure the mount for the line laser on
the tube connectors at 4 Nm.
7. Slide the prismatic reflector
(1)
onto the tool holder.
4712008-04_shd
1
(1) Prismatic reflector
8. Secure the plastic screws
(1)
on the tool holder.
The plastic screws are intended as a stop so the
prismatic reflector cannot slide off the tool hold‐
er by accident. 3 plastic screws are included in
the scope of delivery. The third plastic screw is
intended as a spare.
4712008-05_shd
11
(1) Plastic screws
---Separator---
3.2
Checking the accuracy of the inclina‐
tion measurement (before each cali‐
bration)
Check the accuracy of the grade measurement before
each front radar calibration. This is accomplished by
means of a reverse measurement. To do this, lay the
measuring tool on a table and measure the inclination.
Turn the measuring tool by 180° and measure the in‐
clination again. The difference between the displayed
values
must not exceed 0.3°
. In case of greater devia‐
tion, the measuring tool must be recalibrated. To do
so, select CAL in the settings.
Follow the directions on
the display
. We recommend that you perform an accu‐
racy check and if necessary a calibration of the meas‐
uring tool after extreme temperature variations and
after impact to the tool. After a temperature variation,
the measuring tool must acclimatise for a while before
calibration is performed.
---
SCT 815 | 5 | en