
24/36 Commissioning
Bosch Rexroth AG
, Valve amplifier VT-MSPA, RE 30232-B/08.2020
VT-MSPA2-2X
Standard Expert
Rotary switch
position
Valve type
(two solenoids)
t
Z
G
4Q
t1
t2
t3
t4
GB GA SB SA
B
f
Inv DIn
0-0
no valve
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
0-1
4WRA6...-2X
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
0-2
4WRA10...-2X
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
0-3
4WRZ...-7X
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
0-4
3DREP6...-2X
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
0-5
3DREP6...-2X (SO674)
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
0-6
DBEP6...-1X
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
0-7 ... 3-6
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
3-7
Pump control 1 (0.74 A)
EP (A4CSG)
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
3-8 --- 3-9
‒
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
9-6
Universal (0.8 A)
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
9-7
Universal (1.6 A)
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
9-8
Universal (2.5 A)
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
If no valve type is selected, the LEDs signal the status shown on the left. The yellow
LEDs rotate clockwise in pairs.
The “ready” LED blinks
red/green, if the valve number saved last and the
current rotary switch position do not match!
The amplifier is active and utilizes the parameters of the valve type saved last.
Remedy:
If you wish to change the valve, remove the command value and the enable, press
key
[Set]
> 1 sec and accept the new valve type.
If the rotary switch position was changed accidentally, reset it to the original
valve number.
→ The “ready” LED
is lit green.
In both cases, check the actually connected valve!
Whenever a valve is changed, all changeable parameters are reset to factory
settings!
t
Z/B
G
S
DI