22/36 Commissioning
Bosch Rexroth AG
, Valve amplifier VT-MSPA, RE 30232-B/08.2020
8.3.2 Test jacks
I
B
Actual current in solenoid B (VT-MSPA2-2X), I with VT-MSPA1-2X
I
A
Actual current in solenoid A (VT-MSPA2-2X)
⊥
Reference potential
v
Internal command value or set value
8.4 Selecting the valve types
When setting a valve, the operator generally must ensure that no command value and
no enable is applied to the VT-MSPAx-2X!
The desired valve type has to be selected by means of the two rotary switches, see
Fig. 4 item 4. The left-hand rotary switch sets the tens place, the right-hand rotary
switch the units place of the item. While you make the settings, test jack “v“ outputs
the selected rotary switch position as a voltage value in 100-mV increments.
The following valve types are available.
VT-MSPA1-2X
Standard Expert
Rotary switch
position
Valve type
(one solenoid)
t
Z
G
4Q
t1
t2
t3
t4
GB GA SB SA
B
f
Inv DIn
0-0
No valid valve
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
-
0-1
4WRA6...-2X
●
●
●
●
●
●
–
–
●
–
●
–
–
●
–
●
0-2
4WRA10...-2X
●
●
●
●
●
●
–
–
●
–
●
–
–
●
–
●
0-3
4WRZ...-7X
●
●
●
●
●
●
–
–
●
–
●
–
–
●
–
●
0-4
3DREP6...-2X
●
●
●
●
●
●
–
–
●
–
●
–
–
●
–
●
0-5
4WRPH6...-2X (SO855)
●
●
●
●
●
●
●
●
●
●
●
●
–
●
●
●
0-6
DBEP6...-1X
●
●
●
●
●
●
–
–
●
–
●
–
–
●
–
●
0-7
DBET-6X...G24...
●
●
●
●
●
●
–
–
–
–
–
–
–
●
–
●
0-8
DBET-6X...G24-8...
●
●
●
●
●
●
–
–
–
–
–
–
–
●
–
●
0-9
DBETX-1X...G24-25...
●
●
●
●
●
●
–
–
–
–
–
–
–
●
–
●
1-0
DBETX-1X...G24-8...
●
●
●
●
●
●
–
–
–
–
–
–
–
●
–
●
1-1
(Z)DBE6-2X...
●
●
●
●
●
●
–
–
–
–
–
–
–
●
–
●
1-2
DBEM10...-7X...G24...
●
●
●
●
●
●
–
–
–
–
–
–
–
●
–
●
1-3
DBEM10...-7X...G24-8...
●
●
●
●
●
●
–
–
–
–
–
–
–
●
–
●
1-4
DBEM20...-7X...G24...
●
●
●
●
●
●
–
–
–
–
–
–
–
●
–
●
1-5
DBEM20...-7X...G24-8...
●
●
●
●
●
●
–
–
–
–
–
–
–
●
–
●
1-6
DBEM30...-7X...G24...
●
●
●
●
●
●
–
–
–
–
–
–
–
●
–
●
Indicator lamps
Operational state
Display mode
Meaning
LED DI “digital input“
(yellow)
Normal operation
Permanently ON/OFF
Status of digital input
Setup
Flashing
Standard setup active
Setup
OFF
Expert setup active
Setup
ON/blinking/flickering
Expert setup: Setting of enable input
LED
“ready” (red/
green)
Normal operation
Permanently on green
Module ready for operation
Normal operation
Permanently on red
Error
Normal operation and setup Blinking red/green
Valve number changed (but not confirmed)
Normal operation and setup Blinking red
Invalid valve number
Normal operation
OFF
Module not ready for operation
Setup
Flashing green
Expert setup active