Non-functioning emergency stop devices can
have lethal consequences!
WARNING
Red-yellow emergency stop buttons must function in all operation modes of a
machine or a plant at any time.
Hand-held terminals with red-yellow emergency stop button which are not con‐
nected to a machine, must be stored in a place where they cannot be seen by
the operator in order not to confuse operational devices with non-operational
devices.
●
Unlocking an emergency stop facility must not result in uncontrolled start-
up of machines or plant.
●
The emergency stop button does not replace other safety devices.
●
The emergency stop button on the handheld terminal does not replace the
emergency stop button to be mounted directly on the machine.
●
Some mechanical errors in the emergency stop button and in the stop
button can be recognized at operation only.
Test the function of the emergency stop button the device had been ex‐
posed to mechanical shock (e.g. it had been fallen on the ground).
Additionally, the emergency stop button must be tested cyclically (every
6 months) by activating the emergency stop button.
●
For further information on the emergency stop button and stop button, do
chapter 4 "Technical Data" on page 27
7.3
Enabling Button
7.3.1
General Information
The following chapters contain more detailed information on the enabling but‐
ton:
●
chapter 7.3.2 "Enabling Function" on page 73
●
chapter 7.3.3 "Functioning" on page 74
●
chapter 7.3.4 "Enabling" on page 74
●
chapter 7.3.5 "Panic" on page 75
●
chapter 7.3.6 "Foreseeable Misuse of the Enabling Switch" on page
The pin assingment and a connection example of the enabling device is con‐
tained in
chapter 7.4.6 "X2.2: Enabling Button" on page 82
7.3.2
Enabling Function
The IndraControl VCH 08.1 is equipped with two enabling buttons, one at the
left and one at the right side of the device. This allows a left- and right-hand
operation of the enabling button. Both enabling buttons are switched in parallel
and effect the common safety circuits in the connecting cable in the same way.
Therefore only one of the both enabling buttons must be activated.
The enabling button consists of a 3-stage operating element and an separated
evaluation electronics. An essential feature are the continuous 2-circuit design,
beginning from the actuating elements up to the connection terminals. Different
technologies and circuits are used for the evaluation circuits. Due to the elec‐
tronic switching contacts, their service life does not depend on the load provided
the nominal values of the load (ohmic, inductive and capacitive) are not excee‐
ded.
DOK-SUPPL*-VCH*08.1***-PR02-EN-P
Rexroth IndraControl VCH 08.1 Hand-held Terminal
Bosch Rexroth AG
73/117
Pin Assignments of the IndraControl VCH 08.1
Содержание Rexroth VCH 08.1
Страница 1: ...Electric Drives and Controls Pneumatics Service Linear Motion and Assembly Technologies Hydraulics ...
Страница 12: ...Bosch Rexroth AG DOK SUPPL VCH 08 1 PR02 EN P Rexroth IndraControl VCH 08 1 Hand held Terminal 10 117 ...
Страница 28: ...Bosch Rexroth AG DOK SUPPL VCH 08 1 PR02 EN P Rexroth IndraControl VCH 08 1 Hand held Terminal 26 117 ...
Страница 60: ...Bosch Rexroth AG DOK SUPPL VCH 08 1 PR02 EN P Rexroth IndraControl VCH 08 1 Hand held Terminal 58 117 ...
Страница 92: ...Bosch Rexroth AG DOK SUPPL VCH 08 1 PR02 EN P Rexroth IndraControl VCH 08 1 Hand held Terminal 90 117 ...
Страница 114: ...Bosch Rexroth AG DOK SUPPL VCH 08 1 PR02 EN P Rexroth IndraControl VCH 08 1 Hand held Terminal 112 117 ...
Страница 118: ...Bosch Rexroth AG DOK SUPPL VCH 08 1 PR02 EN P Rexroth IndraControl VCH 08 1 Hand held Terminal 116 117 ...
Страница 119: ...Notes DOK SUPPL VCH 08 1 PR02 EN P Rexroth IndraControl VCH 08 1 Hand held Terminal Bosch Rexroth AG 117 117 ...