296
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
Error output
In addition to the results, errors can also be output via field bus (Table
).
6.4.4.2
Arrangement of the results in the output field of the interface modules
The output area of the data buffer in the interface module is divided according to the following scheme:
X*:T&
Actual value of the TF relative torque, upper/lower
and/or MF relative torque
4
INT32
X*:T&
X*:T&+
Upper limit of MF Relative torque
4
INT32
X*:T&+
X*:TP&
Programmed value of the TF Relative torque, upper 4
INT32
X*:TP&
X*:TP&l
Programmed value of the TF Relative torque, lower 4
INT32
X*:TP&l
X*:T>
Actual value of the monitoring function Max. value
torque
4
INT32
X*:T>
X*:T>+
Limit of the MF Max. value torque
4
INT32
X*:T>+
X*:T<–
Limit of the MF Min. value torque
4
INT32
X*:T<–
X*:T<
Actual value of the monitoring function Min. value
torque
4
INT32
X*:T<
X*:TA–
Lower limit of the MF Average torque value
4
INT32
X*:TA–
X*:TA
Actual value of the MF Average torque value
4
INT32
X*:TA
X*:TA+
Upper limit of the MF Average torque value
4
INT32
X*:TA+
X*:T[–
Lower limit of the MF Torque range
4
INT32
X*:T[–
X*:T[
Actual value of the MF Torque range
4
INT32
X*:T[
X*:T[+
Upper limit of the MF Torque range
4
INT32
X*:T[+
X*:TCh
Actual value of the MF Tightening from above
4
INT32
X*:TCh
X*:TCh+
Limit of the MF Tightening from above
4
INT32
X*:TCh+
X*:TCI-
Limit of the MF Tightening from below
4
INT32
X*:TCI-
X*:TCI
Actual value of the MF Tightening from below
4
INT32
X*:TCI
X*:AO–
Lower limit of the MF Total angle
4
INT32
X*:AO–
X*:AO
Actual value of the MF Total angle
4
INT32
X*:AO
X*:AO+
Upper limit of the MF Total angle
4
INT32
X*:AO+
X*:TAOS
Torque threshold for MF Total angle
4
INT32
X*:TAOS
X*:GA–
Lower limit of the MF Gradient average value
4
INT32
X*:GA–
X*:GA
Actual value of the TF Gradient average value
4
INT32
X*:GA
X*:GA+
Upper limit of the MF Gradient average value
4
INT32
X*:GA+
X*:STS
Actual value of the MF Stick slip
4
INT32
X*:STS
X*:STS+
Limit of the MF Stick slip
4
INT32
X*:STS+
X*:TSTS
Torque threshold for MF Stick slip
4
INT32
X*:TSTS
X*:IN
Actual value of the TF Input
4
INT32
X*:IN
1
Date and time are indicated in seconds counted since 1. 1. 1970, 12:00:00 a.m.
The number 1098773240 corresponds to the following time: Tuesday, 10/26/2004, 6:47:20 a.m.
2
X stands for results step 0 or docu buffers 1 to 3.
Table 6–50:
Results values of channel results during output (Section 2 of 2)
Name
Meaning
Length in
bytes
Format
Example
Name
Table 6–51:
Results output via field bus
Name
Length in
bytes
Format
Comments
Example
Error code
2
Int16
204
Error class
1
Int8
3
Error text
80
ASCII
Filled with space
characters at the end
MSEN 1: Overload
(positive)
Содержание Rexroth Tightening System 350
Страница 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Страница 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...