Electromagnetic and magnetic fields!
People with active medical implants (e.g.
heart pacemakers), passive metallic implants
(e.g. hip prosthesis) and pregnant women
might possibly risk hazards by electromag‐
netic or magnetic fields in the immediate vi‐
cinity of components of the electric drive and
control system and the associated current-
carrying conductors.
Areas in which components of the electric
drive and control system and associated cur‐
rent-carrying conductors are mounted, com‐
missioned and operated may be dangerous
to those people.
WARNING
●
Before entering these areas, the above-mentioned persons should seek
advice from their physician.
●
Observe the occupational safety and health regulations applicable at the
site of operation, for installations equipped with components of the elec‐
tric drive and control system and the associated current-carrying con‐
ductors.
Formation of smoke!
Risk of breathing difficulties due to the forma‐
tion of smoke caused by overloading of the
electric drive motor during longer operation of
the Sytronix system with excessively large
flows and at excessive pressure!
CAUTION
●
Provide motor protection (e.g. overload protection, circuit breaker).
Hot surfaces!
Risk of burning. The Sytronix system heats
up during operation.
CAUTION
●
Let the Sytronix system cool down before touching it.
●
Protect yourself by wearing heat-resistant protective clothing, e.g.
gloves.
Rough, slippery surface!
Hydraulic oil escaping through leaky fittings
and screwed connections causes a risk of
slipping.
CAUTION
●
Check fittings and screwed connections for tightness/leakage.
●
If necessary, retighten fittings/screws and remove escaped oil immedi‐
ately.
12/69
Safety instructions
Sytronix SvP 7020 PFC 03 Variable-Speed Positioning of Hy‐
draulic Axes
Bosch Rexroth AG RE 62314-B_Edition 01
Содержание rexroth Sytronix SvP 7020 PFC 03
Страница 73: ...Notes Sytronix SvP 7020 PFC 03 Variable Speed Positioning of Hy draulic Axes 67 69 ...
Страница 74: ...Notes 68 69 Sytronix SvP 7020 PFC 03 Variable Speed Positioning of Hy draulic Axes ...
Страница 75: ...Notes Sytronix SvP 7020 PFC 03 Variable Speed Positioning of Hy draulic Axes 69 69 ...