EMC Manual ServodynT, D
Switch cabinet structure
35
1070 066 074-101
3.3.3 Configuration with 60/R and VM 100/R
Mains line
3 x 400 V
KM
Motor
lines
Signal
lines and
motor
encoder
(screened)
NC
PLC
24 V control
line
SM
SM
SPM
VM
Mains
line re
actor
Starting
circuit
Mains
filter
Command values,
screened
Direct
measuring
system
(screened)
Relay
24V DC
Braking resistors
Braking contactors
+24 V
X
=
+24V load
+24V logic
230V
X
230V
X
DC/DC
filter
Mains
filter
DC/DC
filter
Filter
terminals
EMC barriers
+24V brake
F
Br
F
Br
= Filter for
holding brake
Fig. 2.2:
Basic configuration of switch cabinet for ServodynT for
medium to high capacity with VM 60/R, VM 100/R