background image

 

R911336853-07_BAL_DOC 

October 21, 2016 

Page 1 of 10 

 
 
 
 
 
 

 

About this Documentation 

1.1

 

Overview – target groups & product phases 

The target groups, product phases and activi-
ties that can refer to this document are marked 
in rounded boxes in the following figure. 
 

Selection

Mounting

(assembly/installation)

Engineering

Commissioning

Operation

De-commissioning

Product phases

Presales Aftersales

Design engineer

Programmer

Technologist

specialist

Mechanic/

electrician

Process

Commissioning engineer

Programmer

Technologist

Process specialist

Machine

operator

Maintenance

technician

Service

Mechanic/

electrician

Disposal company

To select

To prepare

To design

To construct

To unpack

To mount

To install

To parameterize

To program

To configure

To simulate

To optimize

To test

To operate

To maintain

To remove

faults

To create

the program

To dismount

To dispose

Target groups

Activities

 

1.2

 

Intended audience 

This document explains 

technical and service 

personnel of the machine builder

 how to safely 

install the system housing mechanically and 
electrically. This document is not the usage 
manual. 

1.3

 

Availability 

These Instructions are part of the NYS04.1-ST-
01-LMS-SERCOS-NY4078 system housing 
product delivery and must always be available 
for the user. 
If the system housing is handed over to another 
person, these Instructions must be handed over 
as well. 

1.4

 

Included parts 

 

Headers for the 24V System and SE connectors 
are also included. 

1.5

 

Variations 

These  Instructions  apply  to the NYCe 4000 
system housings with the following type code: 

 

NYS04.1-ST-01-LMS-SERCOS-NY4078 

1.6

 

Further available documentation 

 

1.7

 

Additional parts 

Motion  Control Units, host adapter, SERCOS 
III Master module, fan unit, connection cables, 
and more are listed in the project planning 
manuals or on 

www.boschrexroth.com

  

Product Identification and Scope of 
Delivery 

2.1

 

Product identification 

The NYS04.1-ST-01-LMS-SERCOS-NY4078 
has two slots, one for the Motion Control Unit 
(MCU) and one for the SERCOS III Master 
module. 
 
 

 

 

 

  

 

  

 

  

      

 

       

 

 

  

        

 

 

 

  

  

 

        

 

  

  

  

 

  

 

  

   

 

  

 

 

  

   

 

  

 

 
  

  

 

  

 

   

  

 

  

 

   

  

 

  

 

 

    

   

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

  

 

  

      

 

       

 

 

  

        

 

 

 

  

  

 

        

 

  

  

  

 

  

 

  

   

 

  

 

 

  

   

 

  

 

 
  

  

 

  

 

   

  

 

  

 

   

  

 

  

 

 

    

   

 

  

 

 

 

Title and type code 

Material number 

Rexroth NYCe 4000 
Hardware System Manual 
DOK-NY4000-HW***SYSTEM-PRRS-EN-E 

R911337671 

Rexroth NYCe 4000 
Standard Housings & Accessories Manual 
DOK-NY4000-HOUSING*ACC-PRRS-EN-E 

R911337672 

 

Type code

 

Material 
number 

Description 

NYS04.1-ST-01-LMS-SERCOS-
NY4078 

R911172617 

System housing 

DOK-NY4000-LMS*SERCOS*-IT07-
EN-P 

R911336853 

Instructions 

 

EN

 

                Instructions 

 

Rexroth NYS04.1-ST-01-LMS-SERCOS-NY4078 

Bosch Rexroth AG 
Electric Drives and Controls 
Bgm.-Dr.-Nebel-Str. 2 
D-97816 Lohr am Main 
T49 (0)9352-18-0 
T49 (0)9352-18-8400 
www.boschrexroth.com 

 

Содержание Rexroth NYS04.1-ST-01-LMS-SERCOS-NY4078

Страница 1: ...roduct delivery and must always be available for the user If the system housing is handed over to another person these Instructions must be handed over as well 1 4 Included parts Headers for the 24V System and SE connectors are also included 1 5 Variations These Instructions apply to the NYCe 4000 system housings with the following type code NYS04 1 ST 01 LMS SERCOS NY4078 1 6 Further available do...

Страница 2: ...igin 10 Date of manufacture yyWww 11 Rexroth bar code 12 Serial number 13 Company address 14 Test marking 15 CE marking 16 Material number 2 2 Scope of delivery The product delivery consists of the following items NYS04 1 ST 01 LMS SERCOS NY4078 system housing material number R911172617 DOK NY4000 LMS SERCOS IT07 EN P Instructions material number R911336853 Cable connector parts for 24V System SE ...

Страница 3: ...that all pre cautions for a safe operation must be ensured by external components 5 Accessories Spare Parts and Wear Parts The following accessories are available for this system housing The system housing does not contain any re placeable or wear parts In case of failure the entire system housing must be replaced 6 Ambient Conditions Free air flow in vertical direction is required above and below...

Страница 4: ... product intended for the final user EMC Directive 2004 108 EC Maintaining the EMC directive presuppose an EMC adapted installation of the devices within the installation of the machine The complied limit values and standards are specified in the Rexroth Manual of associated product The regulations for the structure and the installation in this manual must be maintained and real ized Tests were ru...

Страница 5: ...quipment on the other end does not have metal parts connect the shield to the equipment ground via a 100 Ω re sistor Never connect the GND or minus wire of these signals to other GND connections otherwise malfunction of the module is possible 9 6 Other interfaces The system housing will always have a Motion Control Unit MCU installed in the leftmost slot and a SERCOS III Master module in the slot ...

Страница 6: ... least by rein forced insulation from all hazardous voltages according to the standard UL61010 1 third edi tion 10 1 Mechanical dimensions The dimensions of the system housings are the following You can see the dimensions of the system housing in the following views The dimen sions given in the view exclude free clearance space required for attached cables accessories and cooling requirements Dime...

Страница 7: ...ousing Then disconnect the 24V System power supply connector Finally disconnect all re maining connectors and protective earth con nections Remove the screws that mount the system housing on the metal surface in the machine 10 4 Protective Earth connection For safety reasons a protective earth connec tion via the threaded earth post is mandatory The protective earth connection must be connected be...

Страница 8: ... required firmware for the MCU and the required gateware for the drive modules installed in the system housing 12 Description of the system housing The system housing has no indicators All in dications LED are on the MCU and SERCOS III Master module See the Instructions of the MCU module and drive modules 4 5 1 2 3 6 1 24V System SE Fan connectors 2 Motion Control Unit slot 3 SERCOS III Master mod...

Страница 9: ...evices mainly contain steel aluminum copper synthetic materials electronic components and modules Recycling Due to their high content of metal most of the product components can be recy cled In order to recycle the metal in the best possible way it is necessary to disas semble the products into individual mod ules The metals contained in the electric and electronic modules can also be recy cled by...

Страница 10: ...R911336853 07_BAL_DOC October 21 2016 Page 10 of 10 Notes ...

Отзывы: