Complete error list
If no improvement is achieved after the recommended solutions, the nutrunner is to be returned with exact
information for repair to Rexroth Service. Before dispatch, contact Rexroth Service
.
Table 11–3: Error description
Error
code
Error
class
Description
Possible cause/consequence
Suggested solution
1
3
Timeout in tightening mode
Communication via integrated controller to
the servo amplifier is outside the admissi-
ble time window during the tightening.
– System is overloaded by other pro-
cesses (results output, ...)
– Servo amplifier defective
Repeat tightening
Update firmware
2
4
Timeout in service mode
Communication via integrated controller to
the servo amplifier is outside the admissi-
ble time window outside of tightening.
– System is overloaded by other pro-
cesses (results output, ...)
– Servo amplifier defective
Reboot nutrunner
Update firmware
10
3
Servo amplifier hardware fault
Servo amplifier defective
11
4
Battery overtemperature
Temperature of the battery pack slide-in
module
Let slide-in battery pack cool down or re-
place it
Adjust tightening and break time (cycle time)
Check ambient temperature
12
4
Overtemperature at the servo am-
plifier
Servo amplifier temperature
Let servo amplifier cool down
Adjust tightening and break time (cycle time)
Check ambient temperature
13
4
Servo amplifier – communication
error
Reboot nutrunner
14
4
Servo amplifier – service error
Start and R/L switch state cannot be read
Reboot nutrunner
15
4
Servo amplifier – incorrect input
voltage
Slide-in battery pack defective
Replace slide-in battery pack
100
0
Tightening program not available
A tightening program selected for execu-
tion cannot be found in the nutrunner mem-
ory.
Generate tightening program
Check tightening program selection
101
1
Gauge bar type label cannot be
read – check plug-in connection
The gauge bar type label cannot be read.
Reboot nutrunner
102
1
Gauge bar type label check sum er-
ror
The electronic type label read by the gauge
bar does not comply with the value stored
in the check sum.
Reboot nutrunner
Update firmware
103
1
Results management access error The internal database is not ready for ac-
cess.
Reboot nutrunner
Update firmware
104
1
No communication with measuring
unit
Communication for measurement recogni-
tion not possible.
Reboot nutrunner
Update firmware
105
1
The gauge bar calibration table
cannot be read
The gauge bar calibration table cannot be
read.
Reboot nutrunner
106
1
Cycle counter cannot be read
The cycle counter cannot be read by the in-
ternal memory.
Reboot nutrunner
Update firmware
107
3
Invalid tightening program
The program file loaded from the internal
memory cannot be read.
Create new or import tightening program
again
108
3
Timeout in tightening mode
No measurement was received in the ad-
missible time window.
– System is overloaded by other pro-
cesses (results output, ...)
Repeat tightening
Update firmware
Содержание Rexroth Nexo
Страница 4: ...4 279 Bosch Rexroth AG Tightening Technology ...
Страница 256: ...256 279 Bosch Rexroth AG Tightening Technology 3 608 870 A47 Nexo cordless Wi Fi nutrunner 3 608 870 A47 2019 ...
Страница 262: ...262 279 Bosch Rexroth AG Tightening Technology 3 608 870 A47 Nexo cordless Wi Fi nutrunner 3 608 870 A47 2019 10 ...
Страница 263: ...3 608 870 A47 Tightening Technology Bosch Rexroth AG 263 279 Nexo cordless Wi Fi nutrunner 3 608 870 A47 2019 10 ...
Страница 264: ...264 279 Bosch Rexroth AG Tightening Technology 3 608 870 A47 Nexo cordless Wi Fi nutrunner 3 608 870 A47 2019 10 ...
Страница 274: ...274 279 Bosch Rexroth AG Tightening Technology 3 608 870 A47 Nexo cordless Wi Fi nutrunner 3 608 870 A47 2019 10 ...
Страница 276: ...276 279 Bosch Rexroth AG Tightening Technology 3 608 870 A47 Nexo cordless Wi Fi nutrunner 3 608 870 A47 2019 10 ...