Control blocks for mobile applications
| Installation
Bosch Rexroth AG, RE 64025-B/2021-08-12
To connect the pressure relief/feed valve to the hydraulic system:
1�
Remove the protective plug or screw plug from the adjustment screw .
2�
Make sure that the sealing surfaces of the fitting are not damaged
3�
Turn the screw fitting clockwise into the thread of the adjustment screw .
When doing so, counter the lock nut and the adjustment screw with an
open-end wrench.
4�
Tighten the screw fitting correctly (observe tightening torque!).