Installation 37/54
3 842 358 814/2017-01, MIT: LU 2,
Bosch Rexroth AG
8.5.8
Install adapter Set AS 2/R-1200, AS 2/R-2200
Fig. 17:
B
A
C
D
X
358 814-08
4x
M
D
= 10Nm
SW10
Install adapter Set AS 2/R-1200, AS 2/R-2200
1.
Install the hose
connector (C) in the
lubricating pin (A).
2.
Remove the side cover of
the drive head.
3.
Insert the lubrication
pin (A) in the correct
position in the bore of
the drive head.
4.
Secure the lubrication pin
with the lock washer (B).
5.
Install 2 O-rings (D) on
the lubrication pin (A) so
that they snap into the
grooves (X).
6.
Install the lubrication line.
7.
Install the side cover of
the drive head.
Please note
:
• Only use 2 equal lubricant pins (do not mix adapter sets).
Different lubricating pins cause unequal distribution through an uneven
fl ow resistance.
• The difference in length of the lubrication lines should be < 20 mm.
Different lubricating line lengths cause unequal lubrication distribution through
an uneven fl ow resistance.
• The lubrication line must always be placed lower than the lubricating pin,
otherwise the lubrication line runs empty (uncontrolled oil spillage, bubbles are
formed in the hoses)
• Fill the lubrication line before commissioning, e.g. by repeatedly pressing the
lubricating device (button in the PLC control) or using the special delivery PURGE
(see page 23), until lubrication comes out of the lubrication pin.
EN
GLISH
358814_2017_01_EN.indd 37
16.01.2017 13:38:19