12.6.2
Excessive temperature of motor housing
State
The housing temperature of the motor rises to unusually high values.
Damage to motor or machine by restarting af‐
ter excessive motor temperature!
NOTICE
●
Liquid-cooled motors may not be restarted or supplied with cold coolant
immediately after a failure of the cooling system and an increased motor
temperature. Risk of damage!
●
Before restarting the motor, wait until the motor temperature has drop‐
ped to approx. 40 °C.
Possible causes
1.
Failure or fault in the fan or cooling system.
2.
The original machining cycle has been changed.
3.
The original motor parameters have been changed.
4.
Motor bearings are worn or defective.
Measures for
1.
Check the fan of MAD motors for proper functioning. Clean as required.
Contact Bosch Rexroth Service in case of a failure.
Check the cooling system of MAF motors for proper functioning. Clean
or rinse the cooling circuit as required. Contact the machine manufactur‐
er in the case of a cooling system failure.
2.
Check the sizing of the drive for changed requirements. Stop operation
in case of overload. Risk of damage!
3.
Restore the original parameters. Check the sizing of the drive if require‐
ments have been changed.
4.
Contact the machine manufacturer.
12.6.3
High motor temperature values, but housing temperature is normal
State
The diagnostic system of the controller shows unusually high winding temper‐
ature values via display or operator software. However, the temperature of
the motor housing is normal.
Possible causes
1.
Wiring error or cable break in sensor cable.
2.
Diagnostic system defective.
3.
Check the wiring and connection of the temperature sensor according to
the interconnection diagram.
4.
Failure of the winding temperature sensor (PTC).
Measures for
1.
Check the diagnostic system at the controller or the control unit.
2.
Check the resistance value of the temperature sensor using a multime‐
ter.
●
Set the measuring device to resistance measurement mode.
●
Shut down the system and wait until the discharging time has
elapsed. Disconnect the temperature sensor from the controller
and connect the wire pair to the measuring device (this also checks
the sensor line). Check the values according to
istic of temperature measurement sensor KTY84-130 (PTC)" on
MAD / MAF Asynchronous Housing Motors
255/265
Operation of MAD/MAF motors
R911295781_Edition 11 Bosch Rexroth AG
Содержание Rexroth IndraDyn MAD100B Rexroth IndraDyn MAD100C
Страница 1: ...MAD MAF Asynchronous Housing Motors Project planning manual R911295781 Edition 11 ...
Страница 10: ...VIII MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911295781_Edition 11 ...
Страница 14: ...4 265 MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911295781_Edition 11 ...
Страница 26: ...16 265 MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911295781_Edition 11 ...
Страница 87: ...MAD MAF Asynchronous Housing Motors 77 265 Technical data R911295781_Edition 11 Bosch Rexroth AG ...
Страница 101: ...MAD MAF Asynchronous Housing Motors 91 265 Technical data R911295781_Edition 11 Bosch Rexroth AG ...
Страница 152: ...142 265 MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911295781_Edition 11 ...
Страница 178: ...168 265 MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911295781_Edition 11 ...
Страница 182: ...172 265 MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911295781_Edition 11 ...
Страница 256: ...246 265 MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911295781_Edition 11 ...
Страница 268: ...258 265 MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911295781_Edition 11 ...
Страница 270: ...260 265 MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911295781_Edition 11 ...
Страница 274: ...Notes 264 265 MAD MAF Asynchronous Housing Motors ...
Страница 275: ...Notes MAD MAF Asynchronous Housing Motors 265 265 ...