12 / 36
IndraControl XFE 01.1
Standards used
Bosch Rexroth AG
R911345570, Edition 06
NOTICE
Electronic damage due to polarity reversal or due to a nominal current that is
too low
The power supply unit has to be able to provide the quadruple nominal
current of the maximum current consumption to ensure a reliable triggering in
case of a failure.
7.2.1
Electrical isolation and isolation of the voltage ranges
Profibus extension module
24
V supply with FE to XF8
DC 1200 V, 1 min.
RT Ethernet extension module
24
V supply with FE to XF40
DC 1200 V, 1 min.
24
V supply with FE to XF41
DC 1200 V, 1 min.
XF40 to XF41
DC 1200 V, 1 min.
Sercos extension module
24
V supply with FE to XF3
DC 1200 V, 1 min.
24
V supply with FE to XF4
DC 1200 V, 1 min.
XF3 to XF4
DC 1200 V, 1 min.
CAN extension module
24
V supply to XF70
DC 1200 V, 1 min.
24
V supply to XF71
DC 1200 V, 1 min.
24
V supply to FE
DC 1200 V, 1 min.
XF70 to FE
DC 1200 V, 1 min.
XF71 to FE
DC 1200 V, 1 min.
XF70 to XF71
DC 1200 V, 1 min.
8
Standards
8.1
General information
The products have been developed according to the German editions of the standards published at the
time of product engineering.
8.2
Standards used
Table 6: Standards used
Standard
Meaning
Edition
IEC 60204-1
Electrical equipment of machines
2007
IEC 61131-2
Programmable logic controllers
2008