8.4 Explosion protection certification (XFE01.1-FB-03, XFE01.1-
FB-20)
II 3G
Ex ec IIC Gc
TÜV 16 ATEX 7949 U
IECEx TUR 16.0049 U
Ex
Explosion protection label
II
Equipment group II: Explosive gas
atmospheres
3G
Equipment category 3: Explosive at-
mosphere (zone 2)
Ex
Explosion protection label
ec
Type of protection "Increased safety"
IIC
Gas group IIC, hydrogen
Gc
Equipment protection level (EPL),
rare and momentary explosive at-
mosphere (zone 2): Flammable
gases, vapors, mists
TÜV...
ATEX EU type examination certificate
IECEx... IECEx certificate number
...U
Component marking
Fig. 8-1: Exemplary type plate
The approval numbers given on the type plate are marked at the end with an "X"
for devices and a "U" for components. "X" indicates special conditions to be ob-
served together with the safety and health regulations given in the standards.
"U" indicates a component (Ex component) that may not be used on its own.
Extension Modules Profibus, RT-
Ethernet, Sercos, CAN
Bosch Rexroth AG
Standards
DOK-CONTRL-XFE**EXTMOD-IT04-EN-P
11/37
Содержание Rexroth IndraControl XFE 01.1 Series
Страница 6: ...Bosch Rexroth AG Extension Modules Profibus RT Ethernet Sercos CAN IV DOK CONTRL XFE EXTMOD IT04 EN P ...
Страница 38: ...Bosch Rexroth AG Extension Modules Profibus RT Ethernet Sercos CAN 32 37 DOK CONTRL XFE EXTMOD IT04 EN P ...
Страница 41: ...Extension Modules Profibus RT Ethernet Sercos CAN Bosch Rexroth AG DOK CONTRL XFE EXTMOD IT04 EN P 35 37 ...
Страница 42: ...Bosch Rexroth AG Extension Modules Profibus RT Ethernet Sercos CAN 36 37 DOK CONTRL XFE EXTMOD IT04 EN P ...
Страница 43: ...Notes Extension Modules Profibus RT Ethernet Sercos CAN Bosch Rexroth AG ...