background image

Artisan Technology Group 

is your source for quality 

new and certified-used/pre-owned equipment

• 

FAST SHIPPING AND 

DELIVERY

• 

TENS OF THOUSANDS OF 

IN-STOCK ITEMS

•  EQUIPMENT DEMOS
• 

HUNDREDS OF 

MANUFACTURERS 

SUPPORTED

•  LEASING/MONTHLY

 

RENTALS

•  ITAR CERTIFIED

           

SECURE ASSET 

SOLUTIONS

SERVICE CENTER REPAIRS

Experienced engineers and technicians on staff 

at our full-service, in-house repair center

WE BUY USED EQUIPMENT

Sell your excess, underutilized, and idle used equipment 

We also offer credit for buy-backs and trade-ins

www.artisantg.com/WeBuyEquipment

                        

REMOTE INSPECTION

Remotely inspect equipment before purchasing with 

our interactive website at

 

www.instraview.com

LOOKING FOR MORE INFORMATION? 

Visit us on the web at

 

www.artisantg.com

    

for more 

information on price quotations, drivers, technical 

specifications, manuals, and documentation

Contact us:

 

 

(888) 88-SOURCE  |  [email protected]  |  www.artisantg.com

SM

View

Instra

Содержание Rexroth IndraControl VCP 05

Страница 1: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Страница 2: ...roject Planning Manual Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 3: ...l rights are reserved in the event of the grant of a patent or the registration of a utility model or design DIN 34 1 Validity The specified data is for product description purposes only and may not be deemed to be guaranteed unless expressly confirmed in the contract All rights are reserved with respect to the content of this documentation and the availability of the product Published by Bosch Re...

Страница 4: ...t Electric Shock by Protective Low Voltage PELV 3 5 3 7 Protection Against Dangerous Movements 3 6 3 8 Protection Against Magnetic and Electromagnetic Fields During Operation and Mounting 3 8 3 9 Protection Against Contact with Hot Parts 3 8 3 10 Protection During Handling and Mounting 3 9 3 11 Battery Safety 3 9 3 12 Protection Against Pressurized Systems 3 10 4 Technical Data 4 1 4 1 Front Panel...

Страница 5: ...es 7 1 7 1 Standard Interfaces 7 2 7 1 1 TTY 20 mA Current Loop X3 SER1 7 4 7 1 1 1 Pin Assignment 7 4 7 1 1 2 Termination 7 5 7 1 2 RS485 X3 SER1 7 6 7 1 2 1 Pin Assignment 7 6 7 1 2 2 Termination 7 6 7 1 3 RS232c X3 SER1 7 8 7 1 3 1 Pin Assignment 7 8 7 1 3 2 Termination 7 8 7 1 4 RS232c X3 SER2 7 9 7 1 4 1 Pin Assignment 7 9 7 2 Field Bus Interfaces 7 10 7 2 1 DeviceNet X2 1 X2 2 7 10 7 2 1 1 P...

Страница 6: ...on 9 1 9 1 Type Code 9 1 9 2 Accessories 9 2 10 List of Figures 10 1 11 Index 11 1 12 Service Support 12 1 12 1 Helpdesk 12 1 12 2 Service Hotline 12 1 12 3 Internet 12 1 12 4 Vor der Kontaktaufnahme Before contacting us 12 2 12 5 Kundenbetreuungsstellen Sales Service Facilities 12 2 12 5 1 Deutschland Germany 12 2 12 5 2 Europa West Europe West 12 3 12 5 3 Europa Ost Europe East 12 4 12 5 4 Afrik...

Страница 7: ...VI Bosch Rexroth AG Electric Drives and Controls Rexroth IndraControl VCP 05 R911299726 02 Contents Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 8: ...t design and the seal running around the rear Thus it is suitable for various applications Furthermore every mounting position is possible Depending on the variant the small operator terminal is equipped either with three serial standard interfaces or with a field bus interface The front panel with keypad consists of a 4 mm aluminium plate with tapered edges and is covered by a chemical resistive ...

Страница 9: ...operating system can be reloaded into the device firm ware download This can be done with the associated programming software VI Composer 1 3 Commissioning Mount the device properly for more information see chapter Dimen sions Then connect the device to the voltage supply and to the control unit or the field bus system if required Artisan Technology Group Quality Instrumentation Guaranteed 888 88 ...

Страница 10: ...hat in any way shape or form uses our products must first read and understand the relevant safety instructions and be familiar with appropriate use If the product takes the form of hardware then they must remain in their original state in other words no structural changes are permit ted It is not permitted to decompile software products or alter source codes Do not mount damaged or faulty products...

Страница 11: ...he above referenced areas of application or under operating conditions other than described in the document and the technical data specified is defined as inappro priate use The small operator terminal may not be used if they are subject to operating conditions that do not meet the above specified ambient conditions This includes for example operation under water in the case of extreme temperature...

Страница 12: ...ible for the safe operation of this equipment If the equipment is resold rented or transferred or passed on to others then these safety instructions must be delivered with the equipment 3 2 Explanations The safety instructions describe the following degrees of hazard seri ousness in compliance with ANSI Z535 The degree of hazard serious ness informs about the consequences resulting from non compli...

Страница 13: ...ualified for the use and operation of the equipment may work on this equipment or within its proximity DANGER High voltage and high discharge current Danger to life or severe bodily harm by electric shock DANGER Dangerous movements Danger to life severe bodily harm or material damage by unintentional motor movements WARNING High electrical voltage due to wrong connections Danger to life or bodily ...

Страница 14: ...given in the documentation of the product with re gard to the use of the delivered components contains only examples of applications and suggestions The machine and installation manufacturer must make sure that the delivered components are suited for his individual application and check the information given in this documentation with regard to the use of the components make sure that his applicat...

Страница 15: ... or tests if the ground wire is not permanently connected to the points of the components provided for this purpose Before working with electrical parts with voltage higher than 50 V the equipment must be disconnected from the mains voltage or power supply Make sure the equipment cannot be switched on again un intended The following should be observed with electrical drive and filter com ponents W...

Страница 16: ...conductor of the electrical equipment always per manently and firmly to the supply mains Leakage current exceeds 3 5 mA in normal operation Use a copper conductor with at least 10 mm2 cross section over its entire course for this safety conductor connection Prior to startups even for brief tests always connect the protective conductor or connect with ground wire Otherwise high voltages can occur o...

Страница 17: ...age this alone cannot be relied upon to ensure complete safety Until the inte grated monitoring functions become effective it must be assumed in any case that faulty drive movements will occur The extent of faulty drive movements depends upon the type of control and the state of operation DANGER Dangerous movements Danger to life risk of injury severe bodily harm or material damage Ensure personal...

Страница 18: ...nst falling or dropping after switching off the motor power by for example mechanically securing the vertical axes adding an external braking arrester clamping mechanism ensuring sufficient equilibration of the vertical axes The standard equipment motor brake or an external brake controlled di rectly by the drive controller are not sufficient to guarantee personal safety Disconnect electrical powe...

Страница 19: ...rts of motors with permanent magnets are being stored operated repaired or mounted If it is necessary for a person with a heart pacemaker to enter such an area then a doctor must be consulted prior to doing so Heart pacemakers that are already implanted or will be implanted in the fu ture have a considerable variation in their electrical noise immunity Therefore there are no rules with general val...

Страница 20: ...e lifting devices and tools correctly and safely For safe protection wear appropriate protective clothing e g safety glasses safety shoes and safety gloves Never stand under suspended loads Clean up liquids from the floor immediately to prevent slipping CAUTION Risk of injury by incorrect handling Do not attempt to reactivate discharged batteries by heating or other methods danger of explosion and...

Страница 21: ...rial dam age CAUTION Danger of injury by incorrect handling of pressurized systems Do not attempt to disassemble to open or to cut a pressurized sys tem danger of explosion Observe the operation instructions of the respective manufacturer Before disassembling pressurized systems release pressure and drain off the fluid or gas Use suitable protective clothing for example safety glasses safety shoes...

Страница 22: ... 575 without Con nector Field Bus Device Approx 58 mm 2 283 without Con nector Degree of Protection Front IP54 Rear IP20 Total Weight Approx 500 g Keypad Type Membrane Keypad with Tactile Feedback Number of Keys 30 Key Area Embossment Edit Keys Navigation Keys Special Keys 15 6 mm x 17 mm H x W Function Keys 16 mm x 17 mm H x W Actuator Travel 0 3 mm Activation Power 3 N Switching Cycles Approx 3 ...

Страница 23: ...d LCD Lifetime 100 000 h Half Life Time of the Backlight 100 000 h Lines 4 Characters Line 20 Display Area 74 mm x 23 mm H x W 2 913 x 0 906 Electrical Data Supply Voltage 24 V DC SELV in Accordance with DIN EN 61131 Residual Ripple Maximum 10 Minimum Voltage 19 2 V Maximum Voltage 30 2 V Power Consumption 0 3 A Connected Load 7 2 W Fuse Semiconductor Fuse Self resetting Protection against Polarit...

Страница 24: ...c According to DIN 66259 T1 CCITT V 28 Transmission Length 0 15 m 49 21 ft Layer stranded Shielded X3 SER1 Electrically Isolated X3 SER2 Not Electrically Isolated Field Bus Interfaces Variable Baud Rates and Data Formats X2 1 X2 2 DeviceNet According to ISO 11898 Electrically Isolated X2 1 X2 2 INTERBUS Electrically Isolated X2 PROFIBUS DP Electrically Isolated Central Unit Central Unit Z84 Clock ...

Страница 25: ...tion Storage Transport 10 to 95 No Condensation Application Area Degree of Pollution 1 Over Voltage Category II Standards and Guidelines Interference Immunity EN 50082 2 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 Emitted Interference EN 55011 EN 55022 Equipment Requirements EN 61131 Storage and Transport EN 61131 Part 2 Power Supply EN 61131 Part 2 Electromagnetic Compatibili...

Страница 26: ... development of all materials e g lubricants in machine tools which may interact with our controls and drives it cannot be completely ruled out that any reactions with the materials used by Bosch Rexroth might occur For this reason before using the respective material a compatibility test has to be carried out for new lubricants cleaning agents etc and our housings our housing materials Artisan Te...

Страница 27: ...4 6 Bosch Rexroth AG Electric Drives and Controls Rexroth IndraControl VCP 05 R911299726 02 Technical Data Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 28: ...l keep a minimum clearance of 30 mm 1 181 around the operator terminal to ensure adequate air cir culation When the operator terminal is installed horizontally please note that ad ditional sources of heat beneath the operator terminal may result in heat accumulation Provide for sufficient heat dissipation Comply with the allowable temperature range listed in the technical data for the use of the o...

Страница 29: ...ric Drives and Controls Rexroth IndraControl VCP 05 R911299726 02 Dimensions 5 1 1 Front Panel Dimensions Fig 5 1 Front panel dimensions Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 30: ...VCP 05 Electric Drives and Controls Bosch Rexroth AG 5 3 Dimensions 5 1 2 Mounting Cutout Fig 5 2 Mounting cutout A Mounting Cutout B Front Panel Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 31: ...g Depth 5 1 3 1 Standard Device Fig 5 3 Side view and mounting depth standard device 1 Front Panel 2 Circumferential Seal 3 Mounting Surface Thickness 1 mm to 14 mm 0 039 to 0 551 4 Threaded Pin DIN 914 M4 x 35 mm 1 378 5 Mounting Clamp Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 32: ...ield Bus Device Fig 5 4 Side view and mounting depth field bus device 1 Front Panel 2 Circumferential Seal 3 Mounting Surface Thickness 1 mm to 14 mm 0 039 to 0 551 4 Threaded Pin DIN 914 M4 x 35 mm 1 378 5 Mounting Clamp Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 33: ...5 6 Bosch Rexroth AG Electric Drives and Controls Rexroth IndraControl VCP 05 R911299726 02 Dimensions Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 34: ...onfirm with Enter 4 Finally press the data release key The new contrast setting becomes effective immediately after the Enter key is pressed If necessary repeat the steps two and three until you are satisfied with the contrast Danger of intoxication If the display is damaged avoid touching swallowing or breathing in the liquids or gases which may leak out Danger of corrosion If the display is dama...

Страница 35: ... device off again 5 Set switch S4 to OFF 6 Then switch the device on again The application will not be lost 6 1 3 Character Attributes The following character attributes can be displayed on the device Normal Flashing 6 1 4 Fonts You are able to use the font Normal and the character set Katakana For the table with the switch positions of the user mode switch see chapter User Mode Switch The switch ...

Страница 36: ... 05 Electric Drives and Controls Bosch Rexroth AG 6 3 Display and Operating Components 6 1 4 1 Character Set Katakana Fig 6 2 Character set Katakana Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 37: ...ing data in the editor The char acters V W and X can be entered when configuring the Shift or Shift Case system variables The key 3 and YZ is used for changing data in the editor The charac ters Y Z and can be entered when configuring the Shift or ShiftCase system variables The key 4 and JKL is used for changing data in the editor The charac ters J K and L can be entered when configuring the Shift...

Страница 38: ...the Shift or Shift Case system variables The key Minus and is used for changing data in the editor The char acters and can be entered when configuring the Shift or ShiftCase system variables The key Cursor left can be programmed to directly select adjacent nodes and I O masks In the editor it moves the cursor one character to the left character selection The key Cursor right can be programmed to d...

Страница 39: ...wed The key Help always shows the current help text online help A flash ing help LED indicates that there is a message The system message is always shown in plain text The key Data release changes from the menu to the editor The inte grated LED is lit during edit mode Pressing data release in edit mode exits the editor The key Enter is used to end the data entry Pressing it during the start mask o...

Страница 40: ... set of identification strips is supplied with the operating device For the labeling use Fig 6 3 Position of the identification strip Fig 6 4 Identification strip labelled and blank The function of the function keys can be freely assigned with soft key functions The function keys can used either as direct keys for menu control of for triggering a function in the control system Single pieces protot...

Страница 41: ...tions for ON or OFF are printed onto the user mode switch S1 S2 S3 S4 Operating Mode I X Standard mode with PLC default upon delivery I X I Standard mode without PLC I Transparent mode with start and stop code of the keys I Transparent mode without stop code of the keys I I Activate download erases the application mem ory and default contrast brightness setting I I I Activate upload Fig 6 5 User m...

Страница 42: ...annel for the upload download logging printer scanner SER2 For the communication channel SER1 the protocol specific use only allows one of the three interface standards to be used Depending on the device variant several interfaces are available to you Type code Available interfaces RS232c X3 SER2 TTY 20mA RS485 RS232c X3 SER1 DeviceNet INTERBUS PROFIBUS DP VCPxx xxxx xxxRS xx xx X X VCPxx xxxx xxx...

Страница 43: ...ic Drives and Controls Rexroth IndraControl VCP 05 R911299726 02 Interfaces 7 1 Standard Interfaces Fig 7 2 Rear view of standard device Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 44: ...pply Voltage 5 Threaded Bolt for Protective Grounding 6 Front Panel 7 Assignment for User Mode Switch 8 User Mode Switch on the Side 9 Battery related information 10 Warning 11 Assignment Connector X1 Supply Voltage 12 Assignment for Termination Switch X3 SER1 RS485 13 Assignment Connector X3 TTY RS485 RS232c 14 Nameplate Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE ww...

Страница 45: ...s crosstalk on the signal lines considerably In idle state signal logic 1 a 20 mA current loop can be measured in the cable 7 1 1 1 Pin Assignment Fig 7 3 25 pin D SUB female connector strip Connector in the small operator terminal 25 pin D SUB female con nector strip Signal Logic 1 Current Flow 20 mA Signal Logic 0 Current Flow Interrupted Pin Designation Function 10 T Transmitted Data Positive P...

Страница 46: ...olarity 16 S2 Power Source 2 Positive Polarity 19 T Transmitted Data Negative Polarity 21 S1 Current Sink 1 Negative Polarity 24 S2 Current Sink 2 Negative Polarity Fig 7 5 Pin assignment TTY 20 mA active The D SUB connector strips must be shielded sufficiently See chapter Shielding D SUB Connectors on page 7 22 When channel SER1 is operated as a current loop the termination for the RS485 must be ...

Страница 47: ...n D SUB female con nector strip 7 1 2 2 Termination For point to point connections always activate the termination For multi point connections only activate the termination at the cable end Signal Logic 1 UA UB 0 3 V i e UA UB Signal Logic 0 UA UB 0 3 V i e UA UB Pin Designation Function 8 T A Transmitted data 9 T B Transmitted data 11 SGND Signal Ground 22 R A Received data 23 R B Received data F...

Страница 48: ...3 510 Ohm R2 150 Ohm R4 120 Ohm Fig 7 9 Resistance values termination RS485 The switch positions for ON or OFF are printed onto the termination switch Only the specified switch positions are permitted S1 S2 S3 S4 Function Transmitter Receiver I I I I Termination is ON Termination is OFF Fig 7 10 Termination switch Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisa...

Страница 49: ...pin D SUB female con nector strip 7 1 3 2 Termination Pin Designation Function 6 TD Transmitted Data 15 CTS Clear to Send 17 RTS Request to Send 18 RD Received Data 25 SGND Signal Ground Fig 7 12 Pin assignment RS232c The D SUB connector strips must be shielded sufficiently See chapter Shielding D SUB Connectors on page 7 22 For the operation of channel SER1 as a RS232 the termination for the RS48...

Страница 50: ...le connector strip Connector in the small operator terminal 25 pin D SUB female con nector strip Pin Designation Function 1 Low Noise Ground 2 TD Transmitted Data 3 RD Received Data 4 RTS Request to Send 5 CTS Clear to Send 7 SGND Signal Ground 20 DTR Data Transfer Request Fig 7 14 Pin assignment of the RS232c interface The D SUB connector strips must be shielded sufficiently See chapter Shielding...

Страница 51: ... Interfaces 7 2 Field Bus Interfaces 7 2 1 DeviceNet X2 1 X2 2 The device can be integrated into the DeviceNet bus using the inter faces available for DeviceNet connections Fig 7 15 Rear view DeviceNet Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 52: ...hreaded Bolt for Protective Grounding 7 Front Panel 8 Assignment Connector X1 Supply Voltage 9 Assignment for User Mode Switch 10 User Mode Switch on the Side 11 Assignment Male Connector X2 1 DeviceNet 12 Assignment Female Connector X2 2 DeviceNet 13 Diagnostic LED 14 Battery related information 15 CE Mark 16 Warning 17 Assignment Female Connector X3 SER2 RS232c Artisan Technology Group Quality I...

Страница 53: ...cifica tion extensions 7 2 1 2 Cable Pin Designation Function 1 nc Not Connected 2 CAN_L CAN_L Bus Line Dominant LOW 3 CAN_GND CAN Ground 4 nc Not Connected 5 nc Not Connected 6 CAN_GND CAN Ground 7 CAN_H CAN_H Bus Line Dominant HIGH 8 nc Not Connected 9 nc Not Connected Fig 7 17 Pin assignment DeviceNet The D SUB connector strips must be shielded sufficiently See chapter Shielding D SUB Connector...

Страница 54: ...nostic LED is located at the rear of the small operator terminal The LED shows the states of the bus system Fig 7 20 Arrangement of the DeviceNet diagnostic LED The diagnostic LED at the small operator terminal has the following functions Baud rate Cable type Cable length 125 kBit s 2 x 1 1 mm 500 m 2 x 0 6 mm 100 m 250 kBit s 2 x 1 1 mm 250 m 2 x 0 6 mm 100 m 500 kBit s 2 x 1 1 mm 100 m 2 x 0 6 m...

Страница 55: ... 05 R911299726 02 Interfaces 7 2 2 INTERBUS X2 1 X2 2 The device can be integrated into the INTERBUS using the interfaces available for INTERBUS connections Fig 7 22 Rear view INTERBUS Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 56: ...hreaded Bolt for Protective Grounding 7 Front Panel 8 Assignment Connector X1 Supply Voltage 9 Assignment for User Mode Switch 10 User Mode Switch on the Side 11 Assignment Male Connector X2 1 Remotebus in 12 Assignment Female Connector X2 2 Remotebus out 13 Diagnostic LEDs 14 Battery related information 15 CE Mark 16 Warning 17 Assignment Female Connector X3 SER2 RS232c Artisan Technology Group Q...

Страница 57: ...Input 3 GND Ground 4 nc Not Connected 5 nc Not Connected 6 DO Data Output Inverted 7 DI Data Input Inverted 8 nc Not Connected 9 nc Not Connected Fig 7 24 Pin assignment INTERBUS Pin Designation Function 1 DO Data Output 2 DI Data Input 3 GND Ground 4 nc Not Connected 5 5 V Power Supply 5 VDC 6 DO Data Output Inverted 7 DI Data Input Inverted 8 nc Not Connected 9 RBST Remote Bus Status Fig 7 25 Pi...

Страница 58: ...Ds at the small operator terminal has the following functions A shielded twisted pair cable cable type LiYCY TP must be used The maximum cable length depends on its use within the INTERBUS topol ogy Designation Color State Function RC Green On Remote Bus Check 5 V Green On Supply Voltage OK Off No Supply Voltage BA Green On Bus Active Off Bus Not Active RD Red On Remote Bus Inactive Fig 7 27 Funct...

Страница 59: ...5 R911299726 02 Interfaces 7 2 3 PROFIBUS DP X2 The interface for PROFIBUS DP connections is available to integrate the device into a PROFIBUS DP structure Fig 7 28 Rear view PROFIBUS DP Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 60: ...c 4 Connector X1 Supply Voltage 5 Threaded Bolt for Protective Grounding 6 Front Panel 7 Assignment Connector X1 Supply Voltage 8 Assignment for User Mode Switch 9 User Mode Switch on the Side 10 Assignment Connector X2 PROFIBUS DP 11 Diagnostic LED 12 Warning 13 Assignment Connector X3 SER2 RS232c Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 61: ...al Plus 5 DGND Data Transmission Potential 6 VP Supply Voltage of Terminators Plus 7 nc Not Connected 8 RxD TxD N Received Data Transmitted Data Minus 9 CNTR N Repeater Control Signal Minus Fig 7 30 Pin assignment PROFIBUS DP The D SUB connector strips must be shielded sufficiently See chapter Shielding D SUB Connectors on page 7 22 Any PROFIBUS DP approved cables specified in the EN 50170 as ca b...

Страница 62: ...agnostics A diagnostic LED is located on the rear of the small operator terminal The LED shows a state of the bus system Fig 7 32 Arrangement of the PROFIBUS DP diagnostic LED The diagnostic LED on the small operator terminal has the following function Baud Rate Cable Length 187 5 kbits s 1000 m 500 kbits s 400 m 1500 kbits s 200 m 3000 to 12000 kbits s 100 m Fig 7 31 Baud rate PROFIBUS DP Color S...

Страница 63: ...ng D SUB connectors 1 D SUB connector 2 Shield 3 Cable clip 4 Cable The shield must be folded back into a flat position over the cable sheath When fastening the cable with the cable clip as much of the shielding as possible must be in contact with the housing and sufficient strain relieve must be ensured Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 64: ...e shipment matches the specifica tions on your delivery note If you notice transport damages or discrepancies please contact our sales department immediately CAUTION Maintenance work in the device is only permissible by skilled stuff If hardware components have to be exchanged please contact the Bosch Rexroth Service or ensure that only skilled stuff changes the re spective components CAUTION The ...

Страница 65: ... as the operating device is initialized clock fre quency application memory size current firmware version program ming software version project name time date number of compilation runs and a random number 1 Hold down an arbitrary key at the operator terminal to generate an error message 2 Read the firmware version now 3 Release the key to complete the initialization procedure of the oper ator ter...

Страница 66: ...n connector Phoenix COMBICON MSTBV 2 5 3 GF A suitable female connector strip of the type Phoenix COMBICON MSTB 2 5 3 STF is supplied Pin Designation Function 1 Low Noise Ground 2 0 V Supply Voltage 0 V 3 24 VDC Supply Voltage 24 VDC Fig 8 2 Pin assignment supply voltage A cable with finely stranded wires with a minimum cross section of 0 75 mm 18 AWG and a maximum cross section of 2 5 mm 14 AWG m...

Страница 67: ... 181 off the outer cable sheath and ap prox 5 mm 0 197 off the wires Fig 8 3 Preparing the cable 2 Fit the wires with wire end ferrules and connect the wires to the con nector Fig 8 4 Connecting the female connector strip If shielded connecting cables are used in the supply voltage area the shield should be connected to pin 1 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURC...

Страница 68: ...e the fuse has been tripped the device must be disconnected from the supply voltage to allow the semiconductor fuse to regenerate At an ambient tempera ture of 20 C 68 F the regeneration takes approximately 20 sec onds The higher the ambient temperature the longer the regeneration takes A separate conductor must always be provided for the protective grounding at the threaded bolt The conductor mus...

Страница 69: ...attery To ensure that the data in the CMOS RAM and the time are preserved it is possible to change the battery under operating voltage Observe the safety notes 1 Remove the threaded bolts of the interfaces 2 Remove the screws on the rear panel of the device and lift off the housing 3 Disconnect the connector from the battery and remove the dead bat tery 4 Plug in the cable of the new battery 5 Pla...

Страница 70: ... panel and display 4 1 Display 4 x 20 characters 30 keys BS 5 Upgrade option 5 1 none N 6 Interface 6 1 DeviceNet DN 6 2 INTERBUS IB 6 3 PROFIBUS DP PB 6 4 Serial RS232 485 TTY 20mA RS 7 Additional design 7 1 none NN 8 Firmware 8 1 Denotes that firmware must be ordered as separate subposition FW 1 2 3 4 6 7 8 9 1 0 5 1 2 3 4 6 7 8 9 2 0 5 1 2 3 4 6 7 8 9 3 0 5 1 2 3 4 6 7 8 9 4 0 5 Example Abbrev ...

Страница 71: ...ies Ordering Designation Material Number Description 1070917922 Battery IKB0053 R911305271 Download cable IKB0033 R911291808 PROFIBUS cable IKB0051 R911305089 Serial cable RS422 IKB0052 R911305090 Serial cable RS232 Fig 9 2 Accessories Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 72: ... female connector strip 7 9 Fig 7 14 Pin assignment of the RS232c interface 7 9 Fig 7 15 Rear view DeviceNet 7 10 Fig 7 16 9 pin D SUB male and female connector strip 7 12 Fig 7 17 Pin assignment DeviceNet 7 12 Fig 7 18 Data line DeviceNet 7 12 Fig 7 19 Baud rate DeviceNet 7 13 Fig 7 20 Arrangement of the DeviceNet diagnostic LED 7 13 Fig 7 21 Function of the DeviceNet diagnostic LED 7 13 Fig 7 22...

Страница 73: ...Rexroth AG Electric Drives and Controls Rexroth IndraControl VCP 05 R911299726 02 List of Figures Fig 9 2 Accessories 9 2 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 74: ...test 4 5 Connecting 8 3 D Default contrast setting 6 2 Device variants 7 1 Diagnostics DeviceNet 7 13 INTERBUS 7 17 PROFIBUS DP 7 21 F Fuse 8 5 I Identification 8 2 K Key Cursor down 6 5 Cursor home 6 6 Cursor left 6 5 Cursor right 6 5 Cursor up 6 5 Data release 6 6 Delete 6 6 Enter 6 6 Help 6 6 Minus 6 5 Page 6 6 Plus 6 5 Print 6 6 Keyboard Edit keys 6 4 Function keys 6 7 Navigation keys 6 5 Spec...

Страница 75: ...iceNet 7 12 INTERBUS 7 16 PROFIBUS DP 7 20 RS232c 7 8 7 9 RS485 7 6 TTY 20 mA 7 4 S Setting the contrast 6 1 Supply voltage 24 V 8 3 T Termination DeviceNet 7 13 PROFIBUS DP 7 21 RS232c 7 8 RS485 7 6 TTY 20 mA 7 5 Termination switch 7 7 U Unpacking 8 1 User mode switch 6 8 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 76: ... 49 0 171 333 88 26 oder or 49 0 172 660 04 06 Unter www boschrexroth com finden Sie ergänzende Hinweise zu Service Reparatur und Training sowie die aktuellen Adressen unserer auf den folgenden Seiten aufgeführten Vertriebs und Servicebüros Verkaufsniederlassungen Niederlassungen mit Kundendienst Außerhalb Deutschlands nehmen Sie bitte zuerst Kontakt mit unserem für Sie nächstgelegenen Ansprechpar...

Страница 77: ...hrexroth de S E R V I C E HOTLINE MO FR von 17 00 07 00 Uhr from 5 pm 7 am SA SO Tel 49 0 172 660 04 06 oder or Tel 49 0 171 333 88 26 S E R V I C E ERSATZTEILE SPARES verlängerte Ansprechzeit extended office time i nur an Werktagen only on working days i von 07 00 18 00 Uhr from 7 am 6 pm Tel 49 0 9352 40 42 22 Vertriebsgebiet Süd Germany South Bosch Rexroth AG Landshuter Allee 8 10 80637 München...

Страница 78: ...si 250 10148 Torino Tel 39 011 224 88 11 Fax 39 011 224 88 30 Italy Italien Bosch Rexroth S p A Via Mascia 1 80053 Castellamare di Stabia NA Tel 39 081 8 71 57 00 Fax 39 081 8 71 68 85 Italy Italien Bosch Rexroth S p A Via del Progresso 16 Zona Ind 35020 Padova Tel 39 049 8 70 13 70 Fax 39 049 8 70 13 77 Italy Italien Bosch Rexroth S p A Via Isonzo 61 40033 Casalecchio di Reno Bo Tel 39 051 29 86 ...

Страница 79: ...ia no 250 sector 3 73429 Bucuresti Tel Fax 40 0 21 255 35 07 40 0 21 255 77 13 Fax 40 0 21 725 61 21 eastel rdsnet ro Romania Rumänien Bosch Rexroth Sp zo o Str Drobety nr 4 10 app 14 70258 Bucuresti Sector 2 Tel 40 0 1 210 48 25 40 0 1 210 29 50 Fax 40 0 1 210 29 52 Russia Russland Bosch Rexroth OOO Wjatskaja ul 27 15 127015 Moskau Tel 7 095 785 74 78 7 095 785 74 79 Fax 7 095 785 74 77 laura kan...

Страница 80: ...exroth India Ltd Electric Drives Controls Advance House II Floor Ark Industrial Compound Narol Naka Makwana Road Andheri East Mumbai 400 059 Tel 91 22 28 56 32 90 91 22 28 56 33 18 Fax 91 22 28 56 32 93 singh op boschrexroth co in India Indien Bosch Rexroth India Ltd S 10 Green Park Extension New Delhi 110016 Tel 91 11 26 56 65 25 91 11 26 56 65 27 Fax 91 11 26 56 68 87 koul rp boschrexroth co in ...

Страница 81: ...moro boschrexroth ca Canada West Kanada West Bosch Rexroth Canada Corporation 5345 Goring St Burnaby British Columbia Canada V7J 1R1 Tel 1 604 205 5777 Fax 1 604 205 6944 Hotline 1 604 205 5777 david gunby boschrexroth ca Mexico Bosch Rexroth Mexico S A de C V Calle Neptuno 72 Unidad Ind Vallejo 07700 Mexico D F Tel 52 55 57 54 17 11 Fax 52 55 57 54 50 73 mariofelipe hernandez boschrexroth com mx ...

Страница 82: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 83: ...ic Drives and Controls P O Box 13 57 97803 Lohr Germany Bgm Dr Nebel Str 2 97816 Lohr Germany Phone 49 93 52 40 50 60 Fax 49 93 52 40 49 41 service svc boschrexroth de www boschrexroth com Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 84: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...