Short circuit due to nonobservance of the ambi-
ent conditions while storing
NOTICE
Also observe the ambient conditions while storing the UPS, refer to
"Ambient conditions" on page 6
Battery damage due to deep discharging!
NOTICE
Due to the UN38.3 specifications on transport, the accumulators of the UPS are
only charged up to 30 % upon delivery. To reach the maximum service life, the
accumulators have to be fully charged once before storage. During storage, the
accumulators have to fully charged once after three to six months.
The lithium ion accumulator is subject to dangerous goods regula-
tions. No further conditions apply to the road transport of accumula-
tors by the user. In case of third-party shipping (e.g. air cargo or for-
warders), there are specific packaging and labeling requirements. A
dangerous goods expert has to be consulted when preparing the
shipped item.
●
Ship the UPS only if the housing is not damaged.
●
When packing the UPS, ensure that it cannot move in the packag-
ing.
●
Transport the UPS only in the original Rexroth packaging. The
Rexroth packaging complies with the legal requirements.
Note the respective national regulations.
15 Ordering information
15.1 Accessories and spare parts
For ordering information on accessories and spare parts, refer to
"Spare parts, accessories and wear parts" on page 6
15.2 Type code
The UPSs are available in different variants according to the following type code:
24/31
Ordering information
IndraControl VAU 02.1 Uninterruptible
Power Supply
Bosch Rexroth AG R911384727_Edition 03
Содержание rexroth IndraControl VAU 02.1
Страница 1: ...IndraControl VAU 02 1 Uninterruptible Power Supply Operating Instructions R911384727 Edition 03 ...
Страница 32: ...28 31 IndraControl VAU 02 1 Uninterruptible Power Supply Bosch Rexroth AG R911384727_Edition 03 ...
Страница 35: ...Notes IndraControl VAU 02 1 Uninterruptible Power Supply 31 31 ...