8.4
Status Displays
8.4.1
Status Displays H1-H4
The following
fig. 8-2 "Status displays H1-H4" on page 64
displays H1-H4:
H1 ("UL")
H4 ("BF")
H3 ("RUN")
H2 ("DIA")
1
5
6
9
1
14
Fig.8-2:
Status displays H1-H4
Pos
LED
Display
Meaning
H1
"UL"
Green
Green~
Green~~
Off
24 V supply (connector X10)
24 V supply is available
The bus connection is kept in the initialization phase by one or several modules
in the initialization phase.
System stop (see table system stop)
No 24 V supply available
H2
"DIA"
Red
Red~
Red~~
Off
Diagnostic display
One or several modules indicate a diagnostics.
System stop (see table system stop)
System stop (see table system stop)
No diagnostics or system stop
Bosch Rexroth AG
DOK-SUPPL*-VAM*11/41**-PR03-EN-P
Rexroth IndraControl VAM 11.1/41.1 Machine Control Panels
64/83
Commissioning
Содержание Rexroth IndraControl VAM 11.1
Страница 1: ...Electric Drives and Controls Pneumatics Service Linear Motion and Assembly Technologies Hydraulics ...
Страница 26: ...Bosch Rexroth AG DOK SUPPL VAM 11 41 PR03 EN P Rexroth IndraControl VAM 11 1 41 1 Machine Control Panels 24 83 ...
Страница 34: ...Bosch Rexroth AG DOK SUPPL VAM 11 41 PR03 EN P Rexroth IndraControl VAM 11 1 41 1 Machine Control Panels 32 83 ...
Страница 48: ...Bosch Rexroth AG DOK SUPPL VAM 11 41 PR03 EN P Rexroth IndraControl VAM 11 1 41 1 Machine Control Panels 46 83 ...
Страница 74: ...Bosch Rexroth AG DOK SUPPL VAM 11 41 PR03 EN P Rexroth IndraControl VAM 11 1 41 1 Machine Control Panels 72 83 ...
Страница 80: ...Bosch Rexroth AG DOK SUPPL VAM 11 41 PR03 EN P Rexroth IndraControl VAM 11 1 41 1 Machine Control Panels 78 83 ...
Страница 82: ...Bosch Rexroth AG DOK SUPPL VAM 11 41 PR03 EN P Rexroth IndraControl VAM 11 1 41 1 Machine Control Panels 80 83 ...