8
Commissioning
8.1
GSD File
With the devices two GSD files according to EN 50170 Part 2 (DP) are provided.
These files contain all data allowing to connect the VAM 11.1 and VAM 41.1 to
any DP master (according to EN 50170 Part 2 (DP)). The master manufacturer
delivers or defines a suitable DP configuration tool with its DP master. A sample
configuration with IndraLogic is described in
chapter 8.8 "Sample Configuration
.
RX010123.GSD is a universal GSD file, which describes the VAM 11.1/
VAM 41.1 Machine Control Panelss as modular slave. You can select this GSD
file in the DP configuration tool via the station name "VAM". The modules must
be configured in the DP configuration tool in the right order. The order of the
modules is described in
chapter 8.7 "Configuration Specifications" on page
RX030123.GSD is a GSD file, which describes the VAM 11.1/VAM 41.1 Ma‐
chine Control Panelss as compact DP slave. This GSD file serves for easy
configuration of the VAM 11.1 and as basic device of the VAM 41.1. If you select
station name "VAM11, VAM41" in the DP configuration tool, the correct con‐
figuration of the modules is automatically displayed.
Please find the GSD files on the Bosch Rexroth web site or contact your sales
representative.
8.2
PROFIBUS DP Address Settings
The station address is set with two BCD rotary switches S1 and S2 (see
8-1 "BCD rotary switches S1 and S2" on page 63
) for the station addresses
1-99. S1 represents the tens digit and S2 the ones digit of the station address.
The address must be set if there is no voltage.
S2
S1
1
5
6
9
1
14
Fig.8-1:
BCD rotary switches S1 and S2
8.3
Baud Rate Setting
The VAM 11.1/VAM 41.1 machine control panels recognize automatically the
baud rate set at the PROFIBUS DP. Supported are baud rates ranging from 9.6
kbaud to 12 Mbaud:
DOK-SUPPL*-VAM*11/41**-PR03-EN-P
Rexroth IndraControl VAM 11.1/41.1 Machine Control Panels
Bosch Rexroth AG
63/83
Commissioning
Содержание Rexroth IndraControl VAM 11.1
Страница 1: ...Electric Drives and Controls Pneumatics Service Linear Motion and Assembly Technologies Hydraulics ...
Страница 26: ...Bosch Rexroth AG DOK SUPPL VAM 11 41 PR03 EN P Rexroth IndraControl VAM 11 1 41 1 Machine Control Panels 24 83 ...
Страница 34: ...Bosch Rexroth AG DOK SUPPL VAM 11 41 PR03 EN P Rexroth IndraControl VAM 11 1 41 1 Machine Control Panels 32 83 ...
Страница 48: ...Bosch Rexroth AG DOK SUPPL VAM 11 41 PR03 EN P Rexroth IndraControl VAM 11 1 41 1 Machine Control Panels 46 83 ...
Страница 74: ...Bosch Rexroth AG DOK SUPPL VAM 11 41 PR03 EN P Rexroth IndraControl VAM 11 1 41 1 Machine Control Panels 72 83 ...
Страница 80: ...Bosch Rexroth AG DOK SUPPL VAM 11 41 PR03 EN P Rexroth IndraControl VAM 11 1 41 1 Machine Control Panels 78 83 ...
Страница 82: ...Bosch Rexroth AG DOK SUPPL VAM 11 41 PR03 EN P Rexroth IndraControl VAM 11 1 41 1 Machine Control Panels 80 83 ...