Assembly 21/60
3 842 558 544/2017-07, MIT: HQ 5/H, HQ 5/XH,
Bosch Rexroth AG
7.5.3
Installing the VE 5/… stop gate
Fig. 6:
557 617-06
VE 5/D-300
VE 5/D-1000
SW13
M
D
=25 Nm
1
2
SW13
M
D
=25 Nm
2
1
2
b+3
+35
b+3
–35
2
b+3
2
b+3
+35
b+3
–35
2
b+3
Installing the VE 5/… stop gate on the HQ 5
Required accessories
• VE 5/D-300 stop gate
3 842 998 517
• VE 5/D-1000 stop gate
3 842 998 805
Install the VE 5/… stop
gate (for the mounting
dimensions See page 18).
Please note:
When using stop gates (before
and after the HQ), the lower
horizontal guard plate needs
to be notched.
• The guard plates are
perforated to make them
easier to remove.
• Protect the cut surface
against corrosion!
• Re-assemble the resulting
individual plates.
EN
GLISH