50/68
Installation
Bosch Rexroth Mellansel AB
, Intallation and maintenance manual, Hägglunds VI, RE 15310-WA/10.2015
3.2.1 Oil connections, V46-C
S
D
S
D
D
C
D
A
2
1
m
P
D
C
2
1
2
m
m
M
M
C
P
A
Fig. 62:
Port
Description
Dimension
Remarks
P*
Main connection
1 1/2”
If P is used as inlet, motor rotates in
direction of the arrow
C*
Main connection
1 1/2”
If C is used as inlet, the motor rotates in
opposite direction of the arrow
D
Drain connection
BSP 3/4”
M
1
Charge pressure conn.
BSP 3/4”
M
2
Charge pressure conn.
BSP 3/4”
Plugged, used as additional charging
port
S
D
Pilot pressure conn.
BSP 1/2”
Plugged
S
A
Pilot pressure conn.
BSP 1/2”
12 bar (170 psi). 6 bar (85 psi) for valve
operating at no flow
P
Pressure point conn.
BSP 1/2”
A
m
, C
m
Pressure point conn.
BSP 3/4”
C
m
Pressure point conn.
BSP 1/2”
D
2
Ext. flushing conn.
BSP 3/4”
Note: Not marked on valve
* SAE-connection J518 C, code 62, 414 bar (6000 psi).