Installation
13/68
Hägglunds VI, RE 15310-WA/10.2015, Intallation and maintenance manual,
Bosch Rexroth Mellansel AB
44-, 64- and 84-series
Max case pressure is 3 bar/43.5 psi (for 1% of the operation time evenly divided,
pressure peaks of max 5 seconds up to 8 bar/116 psi are allowed).
The max permitted case pressure at stand-still is 8 bar/116 psi.
For motors fitted with silicon-rubber seals these pressures must be reduced by 50%.
On the motor there is an arrow which indicates the direction of rotation. When oil is
supplied to port “A” the motor rotates in this direction. The direction of rotation is
also given on the identity plate (see example in the figure below).
IMPORTANT!
With long drain lines, and when flushing through the motor, careful calculations must
be made to determine the line dimensions.
HIGH TORQUE HYDRAULIC MOTOR
TYPE
INDIVID. NO.
DISPLACEMENT
cm /r
3
MAX. PRESSURE
TORQUE
Nm/bar
MK -64 -16300 -AO -RN -XXXX
*
Right hand rotation
(seen from the oil connection
side of the motor)
1.1.1 Common lifting methods
Lifting of motor
Fig. 5: